SAKO SKN-ME 1/2/3kVA line-interactive UPS, embedded technical specification image
SAKO
SAKO's SKN-ME series covers 1, 2 and 3 kVA (650, 1300, 1950 W) 220 VAC line-interactive UPS models with transfer time of 3 ms or less, modified-sinewave output and 30 minutes of standard backup.
On this page
Overview
The SAKO SKN-ME product page presents a line-interactive UPS family for 1000-3000 VA. Listed features are automatic voltage regulation (AVR), a wide input voltage range option, high and low voltage protection, overload and short-circuit protection, cold start without mains, automatic recharge while the UPS is off, a beeping alarm and a colour LED display. The technical specifications are given as an embedded image on the page.
According to the table, input is 220 VAC (160-280 VAC), 50/60 Hz ±1%. Output in inverter mode is 220 VAC ±5%, 50/60 Hz ±1%; the models are 1000 VA/650 W, 2000 VA/1300 W and 3000 VA/1950 W. Transfer time is 3 ms or less and the waveform is modified sine. Protection includes spike and surge suppression, switching to battery when mains exceeds the regulation range, and fuse and current limiting in both modes.
The battery is maintenance-free lead-acid: 4 units of 12 V 7 Ah or 10 Ah in the 1 kVA model, 6 units of 12 V 7 Ah or 9 Ah in the 2 kVA model and 8 units of 12 V 7 Ah or 12 Ah in the 3 kVA model (depending on backup request). Recharge takes 8 hours to 90%, standard backup is 30 minutes and can be customised on demand. Noise is 45 dB or less, operating temperature is -5 to 45 °C, humidity 20-90% and there are 4 sockets.
Key points
- Models: SKN-ME-1KVA (1000 VA/650 W), 2KVA (2000 VA/1300 W), 3KVA (3000 VA/1950 W); line-interactive.
- Input 220 VAC (160-280 VAC), 50/60 Hz ±1%; output 220 VAC ±5%, modified sine.
- Transfer time ≤ 3 ms.
- Battery: maintenance-free lead-acid; 4 (1 kVA), 6 (2 kVA), 8 (3 kVA) 12 V blocks, 7-12 Ah options.
- Recharge: 8 hours to 90% or more; standard backup 30 minutes (customisable).
- Noise ≤ 45 dB; operating -5 to 45 °C; humidity 20-90%; 4 sockets.
- Cold start and automatic recharge when off; fuse and current limiting for overload and short circuit.
Using it in design
- Size the load in watts, noting the low power factor (650/1000 = 0.65); W, not VA, is the limiting value.
- Check compatibility of the modified-sine output with active-PFC power supplies and motor loads; for critical IT loads prefer a pure-sine online UPS.
- The 160-280 VAC input window is an input to assessing suitability for sites with poor mains quality.
- For small offices, network edge or ancillary loads, compare the 30-minute standard backup with the target time; request a battery option for longer runtime.
Who should read it
Designers and purchasing engineers selecting line-interactive UPS for small offices, network edge and ancillary loads.
Document contents
- Features
- Technical specifications (input, output, protection, function)
- Battery
- Environmental and outlets
Publication details
- Authors
- SAKO
- Publisher
- SAKO
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
SAKO SAKO SKN-ME 1/2/3kVA line-interactive UPS, embedded technical specification image. SAKO. https://sakopower.com/skn-me-series-1000-3000va-line-interactive-ups
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.