Syndome Hercules-RT HE-RT series 1-3 kVA rack/tower UPS catalogue
Original title Syndome HE-RT 1–3kVA technical catalogue, p.2
Syndome
Syndome Hercules-RT HE-RT is a 1, 2 and 3 kVA (output power factor 1.0) true online double-conversion UPS: 80-300 V input, THDi <3%, 97% efficiency in ECO mode.
On this page
Overview
The catalogue presents Syndome's Hercules-RT series of the HE-RT-1K, 2K and 3K models. The series is a true online double-conversion topology with DSP control, IGBT converters and high-frequency PWM. In normal mode voltage and frequency are synchronized to the line, in ECO mode the load is fed via bypass within a programmable range, and in frequency mode both voltage and frequency are controlled. It can start without a battery (AC start) and the batteries are easy to replace.
Capacities are 1 kVA/1 kW, 2 kVA/2 kW and 3 kVA/3 kW (PF 1.0). The input voltage range is 80-300 V (80 V at 0-30% load), frequency 50/60 Hz +/-10%, power factor >=0.99, and generator input is 1.5 times the UPS rating. Output voltage is selectable at 208/220/230/240 V +/-1%, harmonic distortion is below 3% on linear and below 5% on non-linear load (the highlights also state THDv below 1% on linear load), and crest ratio is 3:1.
Overload in line mode is 2 min at 100-110%, 1 min at 110-130% and 3 s above 130%. Efficiency is 89% and 91% in AC mode, above 85% and above 88% in battery mode, and 97% in ECO mode. The battery count is 2, 4 or 6 of 12 V 7/9 Ah by model; backup time is over 15 min (load dependent), recharge to 90% takes 4 hours and charging current is at most 1.5 A. AC to DC transfer time is zero.
Physical and general data: dimensions 438x88x430 mm (1K and 2K) and 438x88x610 mm (3K), weights including batteries 10.5, 17.32 and 27.34 kg, noise below 45 and below 50 dB at 1 m, operating temperature 0-40 °C and humidity 0-95% non-condensing. Interfaces are USB, EPO, RS232 and optional SNMP, relay and RS485 cards. Standards are TIS 1291 Parts 1, 2, 3 (Class C2), ISO 9001 and ISO 14001.
Key points
- HE-RT-1K, 2K, 3K: 1, 2, 3 kVA and 1, 2, 3 kW (PF 1.0).
- Input voltage 80-300 V (80 V at 0-30% load); frequency 50/60 Hz +/-10%; input PF >=0.99.
- Input THDi <3%; output THDv <3% (linear), <5% (non-linear).
- Efficiency: AC mode 89%/91%, battery mode >85%/>88%, ECO mode 97%.
- Overload: 2 min at 100-110%, 1 min at 110-130%, 3 s above 130%.
- Battery: 2/4/6 x 12 V 7/9 Ah; backup >15 min; 90% charge in 4 h; charging current 1.5 A.
- Size 438x88x430 mm (1K, 2K) and 438x88x610 mm (3K); weight 10.5-27.34 kg with batteries.
- Generator input 1.5 times UPS rating; AC start without battery.
Using it in design
- With output PF 1.0, compare the load directly in kW; the 3 kVA model gives 3 kW.
- For generator-fed systems size the generator at 1.5 times the UPS rating and use the wide input window (80-300 V).
- When taking the 97% ECO efficiency into energy calculations, remember the load is then fed via bypass and assess load sensitivity.
- In rack layout check the height (88 mm, 2U) and the 3K depth (610 mm); compare weight with batteries against rack load capacity.
- State the SNMP and relay card options in the specification for monitoring.
Who should read it
Electrical designers and resellers selecting 1-3 kVA rack/tower UPS for edge sites, small server rooms and telecom equipment.
Document contents
- System (topology, operation modes)
- Performance and user interface
- Specification table (HE-RT-1K, 2K, 3K)
- Rear panel
- International standards
Publication details
- Authors
- Syndome
- Publisher
- Syndome
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Syndome Syndome HE-RT 1–3kVA technical catalogue, p.2. Syndome. https://www.syndome.com/wp-content/uploads/2024/10/new-catalog-HE-RT.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.