BVT 32-63 A Three-Phase 19-inch Static Transfer Switch, 3U, Touch Screen

Original title BVT 32A40A45A50A63A three-phase19in STS3U technical page

Huizhou BVT Technology

BVT's 32, 40, 45, 50 and 63 A three-phase 19-inch 3U static transfer switch: fully digital control, under 4 ms power-off transfer, under 10 ms priority transfer and 190-250 Vac input.

On this page

Overview

The product page presents Huizhou BVT Technology's 32, 40, 45, 50 and 63 A three-phase 19-inch static transfer switch (STS) with touch screen. The device is described as fully digitally controlled, with strong interference immunity and fast operation. Power-off transfer takes under 4 ms and priority switching under 10 ms; the figure was tested on a purely resistive load and may be slightly longer with no load. The front panel has a display and indicator lights for STS status; a version that switches live and neutral together is available.

Technical data: rated voltage Ua=Ub=Uc=220 V, input range 190-250 Vac, 50/60 Hz, power factor 1. Automatic transfer thresholds are 190 ±5 Vac on undervoltage, 250 ±5 Vac on overvoltage and 45 ±0.2 Hz and 65 ±0.2 Hz on frequency. Over-limit protection shutdown is at ≤120 Vac or ≥260 Vac and at ≤45 Hz or ≥65 Hz. Load current up to 110% runs continuously; above that the unit shuts down immediately. Dielectric strength is 2 kVAC for 1 min.

Environment: noise below 60 dB at 1 m, ambient temperature -25 to 50 °C, humidity 0-90% non-condensing, IP20, altitude up to 3000 m, with output reduced by 2% per 100 m between 2000 and 3000 m. Protections are input under- and overvoltage, output overload, over-temperature and short circuit.

Key points

  1. Ratings 32, 40, 45, 50 and 63 A; 3U, 19-inch rack, touch screen.
  2. Power-off transfer ≤4 ms; priority transfer ≤10 ms (resistive load).
  3. Rated 220 V (Ua=Ub=Uc), input 190-250 Vac, 50/60 Hz, PF 1.
  4. Transfer thresholds: 190 ±5 Vac, 250 ±5 Vac, 45 ±0.2 Hz, 65 ±0.2 Hz.
  5. Overload: continuous up to 110%, immediate shutdown above.
  6. Ambient -25 to 50 °C, humidity 0-90%, IP20, noise ≤60 dB.
  7. Altitude ≤3000 m; output falls 2% per 100 m between 2000 and 3000 m.
  8. A version switching live and neutral together is available.

Using it in design

  • In small rooms, place the STS in a 3U rack position between two UPS units for single-corded loads.
  • Compare the load's tolerance time with the 4 ms and 10 ms values.
  • Because the unit shuts down immediately above 110%, keep continuous load current below the rating.
  • Choose the live/neutral switching version where neutral isolation between sources is needed.
  • Apply altitude derating (2% per 100 m) for sites above 2000 m.

Who should read it

Electrical engineers designing A/B power transfer for small critical rooms.

Document contents

  1. Product description and features
  2. Technical parameters
  3. Environment and protection functions

Publication details

Authors
Huizhou BVT Technology
Publisher
Huizhou BVT Technology
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Huizhou BVT Technology BVT 32A40A45A50A63A three-phase19in STS3U technical page. Huizhou BVT Technology. https://www.bvtpower.com/fr/three-phase-sts-amp-sts-cabinet/bvt_32a_40a_45a_50a_63a_three_phase_19_inch_static_transfer_switch_3u_with_touch_screen_164.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.