ONCCY EATS5 250-630U 160-630 A PC Class Automatic Transfer Switch

Original title ONCCY EATS5 250-630U product technical parameters (linked 22 July 2026 datasheet)

ONCCY

ONCCY EATS5 is a PC class automatic transfer switch (ATS) from 160 to 630 A in 2P/3P/4P: 250U/400U/630U frames, AC-33B, 10 kA short-circuit rating, 17,000 mechanical and 6,000 electrical operations.

On this page

Overview

The page presents the 250U, 400U and 630U frames of the ONCCY EATS5 automatic transfer switch series. The switches transfer between a normal and a backup supply and are aimed at main and sub-main power-transfer panels. Rated-current options are 160, 180, 200, 225 and 250 A for the 250U; 250, 315 and 400 A for the 400U; 500 and 630 A for the 630U.

All frames share a two-position mechanism, 2, 3 or 4 poles, 7 A rated control current, 10 kA rated short-circuit current, 8 kV impulse withstand voltage and utilization category AC-33B. Mechanical life is 17,000 and electrical life 6,000 operations. The working mode can be self-input/self-recovery or standby-power priority; utility-generator function and communication are optional.

Suggested applications include commercial main boards, factories, data centres and larger server rooms, hospitals, generator-backed emergency power and critical ventilation and refrigeration loads. The page is at product-introduction level: it gives no transfer time, standard number or coordination tables.

Key points

  1. Three frames: 250U (160-250 A), 400U (250-400 A), 630U (500-630 A); 2P, 3P or 4P.
  2. Two-position mechanism; rated control current 7 A.
  3. Rated short-circuit current 10 kA; impulse withstand voltage 8 kV.
  4. Utilization category AC-33B, PC class ATS.
  5. Life: 17,000 mechanical and 6,000 electrical operations.
  6. Working modes: self-input/self-recovery or standby-power priority.
  7. Optional utility-generator function and communication.

Using it in design

  • Compare the ATS 10 kA short-circuit rating with the prospective fault current at its busbar; coordinate with upstream protection if it is insufficient.
  • For the main generator inlet of a data hall, choose return and priority mode to suit the operating scenario.
  • Compare the 6,000 electrical-operation life with the test and maintenance transfer frequency.
  • Because transfer time is not listed, obtain it from the manufacturer where the transfer sits ahead of a UPS and ride-through matters.

Who should read it

Electrical engineers designing generator transfer at main and sub-main distribution level.

Document contents

  1. Description
  2. Key Features
  3. Technical Parameters
  4. Applications

Publication details

Authors
ONCCY
Publisher
ONCCY
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ONCCY ONCCY EATS5 250-630U product technical parameters (linked 22 July 2026 datasheet). ONCCY. https://onccy.com/product/eats5-250-630u-160-630a-2p3p4p-pc-class-automatic-transfer-switch

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.