Technical guideFree to readYear not stated

Ronk ATS20012 product specifications

Ronk Electrical Industries

Ronk ATS20012 is a 200 A, 240 VAC, single-phase, NEMA 4/12 UL 1008 automatic transfer switch for optional standby systems, weighing approximately 85 lb.

On this page

Overview

The Ronk ATS is an automatic transfer switch designed to UL 1008 that switches between utility and backup power sources. Model ATS20012 is the 200 A, 240 VAC, single-phase version offered for optional standby system use. The enclosure is NEMA 4/12; the manufacturer calls it weather-resistant and suitable for indoor and outdoor installation.

The product description targets residential and lite commercial applications. The switch detects power loss, transfers quickly and safely to the alternate source, returns to normal operation when utility power is restored and prevents backfeeding. The digital controller comes factory set with common trip time delays, parameters are easy to change and manual override is possible. An optional breaker (not UL listed) is available.

The page links to the RONK ATS 100-200A manual, a technical specification, a limited warranty and terms. Because it covers a single product line, data-centre-level detail such as protection coordination or short-circuit withstand does not appear on the page; those values sit in the technical specification.

Key points

  1. Model ATS20012: 200 A, 240 VAC, single-phase.
  2. System application: optional standby.
  3. Enclosure NEMA 4/12; rated UL 1008, NEMA 4 standard.
  4. Approximate weight 85 lb.
  5. Digital controller factory set with common trip time delays; parameters adjustable and manual override available.
  6. Optional breaker (not UL listed) available.
  7. Automatic return on utility restoration and backfeed prevention.

Using it in design

  • Match the 200 A load current and phase (single-phase for this model) to the load panel.
  • Before using in data-centre critical loads, confirm the residential and lite commercial scope, transfer time and short-circuit withstand in the technical specification.
  • With a NEMA 4/12 enclosure the switch suits outdoor ancillary loads; follow the manual for installation rules.
  • Adjust transfer delays from the factory-set controller parameters to the generator load acceptance strategy.

Who should read it

Electrical designers choosing automatic transfer switches for small edge loads, ancillary buildings and residential or lite commercial sites.

Document contents

  1. Overview
  2. Features
  3. Specifications
  4. Documents

Publication details

Authors
Ronk Electrical Industries
Publisher
Ronk Electrical Industries
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Ronk Electrical Industries Ronk ATS20012 product specifications. Ronk Electrical Industries. https://www.ronkelectrical.com/en/product/products-switches-automatic-transfer/200a-1ph-240vac-optional-standby--ATS20012

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.