Technical guideFree to readYear not stated

APS Energia Product Catalogue: Industrial UPS, Rectifier and Inverter Systems

Original title APS Energia: Katalog Produktów 2025

APS Energia

Product catalogue of Polish APS Energia: buffer rectifiers, inverters, static switches and UPS systems, including the modular transformer-less UPS MODULA 20-120 kVA with 0.99 input power factor and n+1 redundancy.

On this page

Overview

The catalogue presents the guaranteed-power product range of APS Energia, active in the energy sector for 31 years. The company builds systems for power, industry, rail transport, defence, nuclear, oil and gas, energy storage and renewables, and the group has 10 companies. Content covers buffer rectifiers, thyristor rectifiers, DC converters, discharge resistors, industrial inverters, static switches, UPS systems, frequency converters, motor supply systems and monitoring systems.

The UPS section describes a system built to customer order from BFIz inverters, SKB static switches, PBI rectifiers with batteries, and transfer and distribution boards. Standard parameters: single-phase 220/230/240 V or three-phase 380/400/415 V input (+10%/-15%), 50/60 Hz, DC side 24-700 V, static voltage stability ±1%, dynamic ±5% in 10 ms, THDu below 2% on linear and below 5% on non-linear load, inverter efficiency 85-95%, power-factor range 0.7-1.0, crest factor 3:1 (5:1 option), overload <110% continuous, ≤125% for 10 min, ≤150% for 1 min. Batteries are 12 V VRLA blocks.

The MODULA section describes a modular transformer-less UPS: 20 to 120 kVA in 20 kVA/16 kW modules (cos φ 0.8), VFI double conversion, hot-plug/hot-swap modules, n+1 redundancy through one extra module, an active IGBT rectifier giving 0.99 input power factor (0.97 below 25% load) and THDi below 6% (load above 75%). Targets include data centres, DCS/PLC systems, banking and telecom. Interfaces are RS485, USB and Ethernet; protocols are Modbus RTU, IEC 60870-5-103, IEC 61850 and SNMP.

Key points

  1. The catalogue is published in Polish; product groups: rectifiers, DC converters, inverters, static switches, UPS, frequency converters, motor supply, monitoring.
  2. UPS standard input: 220/230/240 V single phase or 380/400/415 V three phase, +10%/-15%, 50/60 Hz; DC 24-700 V.
  3. Output: static ±1%, dynamic ±5% (10 ms), THDu <2% (linear) and <5% (non-linear), frequency ±0.1%.
  4. Overload: <110% continuous, ≤125% 10 min, ≤150% 1 min; HC version ≤250% 15 s and short-circuit current up to 9×In.
  5. Inverter efficiency 85-95%, output cos φ 0.7-1.0, crest factor 3:1 (5:1 option).
  6. UPS MODULA: 20-120 kVA, 20 kVA/16 kW module (cos φ 0.8), n+1 configuration.
  7. MODULA input: PF 0.99 (0.97 below 25% load), THDi <6% (load >75%), 3x400 V, nominal 17 kW (no charging), maximum 20 kW.
  8. DC input range 454-605 V (2x126 cells) and 475-633 V (2x132 cells).
  9. Protocols: Modbus RTU, IEC 60870-5-103, IEC 61850, SNMP; event archive on SD card.

Using it in design

  • For n+1 in a modular UPS, choose the module count so one 20 kVA module is spare, and record the 120 kVA ceiling in the growth plan.
  • Set the battery cell count (2x126 or 2x132) together with the DC input window.
  • Use 20 kW (with charging) and 17 kW (without) as the input power for generator and cable calculations.
  • Add IEC 61850 and Modbus protocol requirements to the specification for industrial control systems.
  • The catalogue's efficiency range (85-95%) is not tied to a load point; request the detailed curve from the maker.

Who should read it

Electrical engineers selecting guaranteed-power systems for industrial, energy and data-centre sites.

Document contents

  1. Prostowniki buforowe (buffer rectifiers)
  2. Prostowniki tyrystorowe
  3. Przetwornice prądu stałego
  4. Falowniki przemysłowe (industrial inverters)
  5. Łączniki statyczne (static switches)
  6. Systemy UPS
  7. Beztransformatorowe systemy UPS MODULA
  8. Przetwornice częstotliwości
  9. Systemy nadzoru i urządzenia pomocnicze

Publication details

Authors
APS Energia
Publisher
APS Energia
Year
Year not stated
Document language
Polish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

APS Energia APS Energia: Katalog Produktów 2025. APS Energia. https://apsenergia.pl/app/uploads/2025/10/APS_Energia_Katalog_Produktow_PL.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.