Technical guideFree to readYear not stated

ELEN: Russian product catalogue, E6 specifications

Enel Enerji

Enel Enerji's Russian ELEN catalogue table on pp.30-31 covers the 20 and 40 kVA UPS family at power factor 0.9; the 40 kVA is a separate column and half-load efficiency is 95%.

On this page

Overview

Enel Enerji's Russian-language ELEN catalogue is the manufacturer source for the model, power and installation scope of its UPS family. The pages used are PDF pp.30-31, and the table covers the 20 and 40 kVA family with power factor 0.9; the 40 kVA is a discrete column.

Weight is not published for the 40 kVA in the table. Half-load efficiency is explicitly defined as 95%; for full load only an 'up to' value is given, so full-load efficiency is not relied on. The PDF metadata is dated 2019. Module, cabinet and battery scopes should be assessed separately.

Key points

  1. The table covers a 20 and 40 kVA UPS family with power factor 0.9.
  2. The 40 kVA is a discrete column; weight is not published.
  3. Half-load efficiency is defined as 95%.
  4. For full load only an 'up to' value is given.
  5. The PDF metadata is dated 2019; the catalogue is published in Russian.

Using it in design

  • With power factor 0.9, convert the 20 and 40 kVA ratings to kW for capacity calculations.
  • Use efficiency at the half-load point (95%) and request a separate full-load value from the manufacturer.
  • Write module, cabinet and battery scopes as separate items in the specification.
  • Obtain the 40 kVA weight from the manufacturer for floor-loading calculations.

Who should read it

Electrical designers and procurement teams evaluating the Enel Enerji UPS family.

Publication details

Authors
Enel Enerji
Publisher
Enel Enerji
Year
Year not stated
Document language
Russian
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Enel Enerji ELEN: Russian product catalogue, E6 specifications. Enel Enerji. https://enel.com.tr/katalog/elen-ru.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.