IMPULS FORWARD 33 Series UPS: Manufacturer Model Page

Original title ИБП ИМПУЛЬС серия ФОРВАРД 33

Impuls (Импульс)

The Russian manufacturer Impuls's FORWARD 33 three-phase double-conversion UPS page: five models of 10, 15, 20, 30 and 40 kVA/kW, 19-inch rack mounting, 3/3, 3/1 and 1/1 configurations and up to 4 units in parallel.

On this page

Overview

The page presents the Impuls FORWARD 33 series: five double-conversion (on-line) models from 10 kW/kVA to 40 kW/kVA. Each model is listed with 1 or 3 phases at input and output; the models are FORWARD 3310, 3315, 3320, 3330 and 3340 at 10, 15, 20, 30 and 40 kW/kVA, with product codes FV10331, FV15331, FV20331, FV30331 and FV40331.

The highlighted features are installation in a 19-inch rack or cabinet with easy server integration, a 7-inch touch graphic display, an intelligent battery charge and discharge process, flexible 3/3, 3/1 and 1/1 configurations, parallel operation of up to 4 units, compact power modules (a 30 kVA module is only 3U high) and RS485 (Modbus-RTU), RS232, USB and dry-contact interfaces.

The page gives no detailed technical data such as nominal voltage, physical dimensions and weight, so a full data sheet and installation manual should be requested separately when selecting the series. It is a Russian-language manufacturer product page; the brand targets the Russian and CIS market.

Key points

  1. The series has five models: FORWARD 3310, 3315, 3320, 3330, 3340; 10, 15, 20, 30 and 40 kW (kVA equal).
  2. All models are double-conversion (on-line); input and output phases are selectable as 1 or 3.
  3. Configuration options are 3/3, 3/1 and 1/1.
  4. Up to 4 units can run in parallel.
  5. The 30 kVA power module is only 3U high and mounts in a 19-inch rack or cabinet.
  6. Interfaces: RS485 (Modbus-RTU), RS232, USB and dry contacts; the display is a 7-inch touch screen.
  7. The page does not give nominal voltage, dimensions or weight.

Using it in design

  • For small and medium data rooms and rack-based installations, include 19-inch-mounted 10-40 kVA double-conversion options and expansion to 4 parallel units in the comparison.
  • Match the phase configuration (3/3, 3/1, 1/1) to the building supply and load distribution.
  • Write the Modbus-RTU and dry-contact interfaces into the building monitoring integration specification.
  • For dimensions, weight, efficiency and battery details, request the full data sheet and manual from the manufacturer; the model page fields do not contain them.

Who should read it

Electrical designers seeking rack-mounted double-conversion UPS options in the 10-40 kVA range, and procurement specialists reading Russian sources.

Document contents

  1. Series features
  2. FORWARD 33 model catalogue (3310, 3315, 3320, 3330, 3340)

Publication details

Authors
Impuls (Импульс)
Publisher
Impuls (Импульс)
Year
Year not stated
Document language
Russian
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Impuls (Импульс) ИБП ИМПУЛЬС серия ФОРВАРД 33. Impuls (Импульс). https://impuls.energy/ibp/online/forvard-33/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.