ONLINE USV-Systeme XANTO 6000-20000 user manual (June 2025)

Original title XANTO 6000–20000 Benutzerhandbuch 06/2025

ONLINE USV-Systeme AG

The ONLINE USV-Systeme XANTO manual covers a VFI-SS-111 class 6-20 kVA double-conversion UPS series with installation, parallel operation and technical tables; ECO efficiency 97-98%.

On this page

Overview

The manual, dated June 2025, covers the XANTO series from German manufacturer ONLINE USV-Systeme AG (active since 1988). Four models are covered: XANTO 6000 (6000 VA / 4800 W), XANTO 10000 (10000 VA / 8000 W), XANTO 10000 3/1 (10000 VA / 9000 W) and XANTO 20000 3/1 (20000 VA / 18000 W). The 6000 and 10000 are single-phase and combined rack-tower (2U); the 3/1 models are three-phase in, single-phase out. The series is true double conversion and VFI-SS-111 class per EN 62040-3.

The manual divides into installation (tower and rack mounting, battery connection, electrical installation), operation (control panel, LED and menu settings, operating states), communication (RS-232, USB, SNMP/AS400 card slot, emergency power-off EPO, DataWatch software), maintenance (battery replacement, testing), fault codes and technical data. For redundancy and parallel operation up to three units can be connected as n+1; if load exceeds nominal power the group switches automatically to parallel mode and redundancy is lost.

According to the technical table, nominal input is 230 V (6000 and 10000) or 400 V (3/1); the input voltage range depends on load, 110-300 V at 50% load and 176-300 V at full load (176-276 V L-N on the 3/1). Normal-mode efficiency is above 94% (6000, 10000) and above 92% (3/1); high-efficiency (ECO) mode is above 98% and 97%; battery mode is above 91%, 87% and 88%. Maximum losses are 600, 1000, 1440 and 2880 W. Output is 230 V ±1% (battery mode), adjustable to 208/220/230/240 V; at 208 V power derates by 20%.

On batteries: the 6000 uses a pack of 16 x 12 V / 7 Ah and the 10000 a pack of 16 x 12 V / 9 Ah (192 V); the 3/1 models use 240 V (20 x 12 V / 9 Ah). Typical bridging times are given at 50% and 100% load (cos φ 0.7) by model and number of extra battery packs; for example the XANTO 6000 gives 17 / 6 minutes with one pack and 139 / 58 minutes with five. Ambient is 0-40 °C, 0-95% humidity, IP21 protection and a 3-year warranty including battery.

Key points

  1. Models: XANTO 6000 (6000 VA/4800 W), 10000 (10000 VA/8000 W), 10000 3/1 (10000 VA/9000 W) and 20000 3/1 (20000 VA/18000 W).
  2. Class VFI-SS-111 (EN 62040-3); safety EN 62040-1, EMC EN 62040-2, CE.
  3. Efficiency: normal mode above 94% and 92%, ECO above 98% and 97%, battery mode above 91%, 87% and 88%.
  4. Maximum losses: 600 W, 1000 W, 1440 W and 2880 W.
  5. Input range 110-300 V at 50% load; 176-300 V at full load (176-276 V L-N on 3/1).
  6. Output adjustable to 208/220/230/240 V; 20% power derating at 208 V.
  7. Up to 3 units in n+1 redundancy or parallel; in parallel for example 3 x XANTO 6000 = 18000 VA.
  8. Battery pack 192 V (6000, 10000) or 240 V (3/1); XANTO 6000 bridging time is 17/6 min with 1 pack and 139/58 min with 5 packs (50%/100% load).
  9. MTBF 47,000 hours (6000, 10000) and 45,000 hours (3/1), excluding battery; IP21; 3-year warranty.

Using it in design

  • In the 6-20 kVA range take kW capacity per model: 4800 W for the XANTO 6000, 8000 W for the 10000 (9000 W for 3/1) and 18000 W for the 20000 3/1; kVA is not equal.
  • For n+1 redundancy use up to three units of equal power, and make it a design rule that redundancy is lost if load exceeds a single unit's power.
  • In the energy budget keep normal-mode and ECO-mode efficiency apart; assess the protection level of ECO mode against load sensitivity.
  • Take battery autonomy from the manual's 50% and 100% load (cos φ 0.7) table and add the extra battery pack weight (47-125 kg) to floor loading.
  • On the 3-phase in, 1-phase out model distribute phase load evenly; input current is 3 x 24.9 A and 3 x 49.8 A.

Who should read it

Electrical designers installing UPS in small and mid-size data rooms, and installation and maintenance teams.

Document contents

  1. Introduction
  2. Safety warnings
  3. Installation
  4. Operation
  5. Communication and interfaces
  6. Maintenance
  7. Troubleshooting
  8. Support
  9. Technical data
  10. Warranty

Publication details

Authors
ONLINE USV-Systeme AG
Publisher
ONLINE USV-Systeme AG
Year
Year not stated
Document language
German
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ONLINE USV-Systeme AG XANTO 6000–20000 Benutzerhandbuch 06/2025. ONLINE USV-Systeme AG. https://www.online-usv.de/sites/default/files/2025-06/2506-benutzerhandbuch-usv-xanto-6000-20000.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.