PowerWalker VFI 10000 AT Single-Phase Online UPS
Original title PowerWalker VFI 10000 AT: 10122249
PowerWalker (BlueWalker GmbH)
PowerWalker VFI 10000 AT is a 10000 VA / 9000 W single-phase double-conversion tower UPS with 0.9 output power factor, 93% line-mode and 96% ECO-mode efficiency, 20 x 12 V 9 Ah batteries and a built-in maintenance bypass.
On this page
Overview
The product page presents the 10000 VA model (SKU 10122249) of the PowerWalker VFI AT series. The series is an online double-conversion UPS family for commercial applications, with wide input voltage and frequency ranges that allow operation on unstable networks. A built-in maintenance bypass switch (MBS), generator compatibility, EPO or ROO function, external battery connection (EBM), a configurable charger and an intelligent slot are standard. The series comes in 1000, 2000, 3000, 6000 and 10000 VA.
Technical data: 10000 VA / 9000 W, single-phase in and out (1-1), pure sine wave, output power factor 0.90, input power factor above 0.99 at full load, input voltage window 110-300 V AC at 40% load and 176-300 V AC at 100% load, nominal output 208/220/230/240 V AC, crest ratio 3:1, battery-mode frequency ±0.1 Hz. Full-load efficiency is 93% in line mode, 91% in battery mode and 96% in ECO mode. Transfers: line to battery 0 ms, to bypass 0 ms, to and from ECO mode 10 ms.
Batteries are 20 x 12 V / 9 Ah; the charger is adjustable at 1 A / 2 A / 4 A with 4 hours to 90%. Noise is below 55 dB and the operating temperature 0-40 °C. Product size is 412x196x702 mm at 75.5 kg; the package is 566x350x956 mm at 82 kg. Accessories include an AS400 card, SNMP card 2, IEC cables, input power cables, RS-232 and USB cables and the BP AT240T-40x9Ah external battery pack.
Key points
- 10000 VA / 9000 W, 1-1 phase, tower; output power factor 0.90; input power factor above 0.99.
- Input 110-300 V AC (40% load) and 176-300 V AC (100% load); output 208/220/230/240 V AC.
- Efficiency: 93% line mode, 91% battery mode, 96% ECO mode.
- Transfer: line mode to battery 0 ms; bypass 0 ms; to and from ECO 10 ms.
- Batteries 20 x 12 V / 9 Ah; charge current 1/2/4 A adjustable; 4 h to 90%.
- Size 412x196x702 mm; weight 75.5 kg (82 kg packed); noise below 55 dB; 0-40 °C.
- Built-in maintenance bypass, generator compatibility, EPO/ROO, external battery connector and management card slot.
- Accessories: SNMP card 2, AS400 card, BP AT240T-40x9Ah battery pack.
Using it in design
- To balance a 9 kW single-phase load on a three-phase supply, set the phase assignment at design stage.
- Check floor and layout for the 75.5 kg weight and 196x412 mm footprint.
- Compare the 10 ms ECO transfer with load tolerance.
- On generator-fed sites, use the wide 110-300 V AC input window and set the charge current.
- Calculate the number of BP AT240T-40x9Ah external packs for the required autonomy.
Who should read it
Electrical designers and procurement engineers seeking mid-power single-phase online UPS.
Document contents
- General Features
- Input
- Output
- Technical Details
- Batteries and Autonomy
- Communication
- Logistics
- Accessories
- Downloads
Publication details
- Authors
- PowerWalker (BlueWalker GmbH)
- Publisher
- PowerWalker (BlueWalker GmbH)
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
PowerWalker (BlueWalker GmbH) PowerWalker VFI 10000 AT: 10122249. PowerWalker (BlueWalker GmbH). https://powerwalker.com/product/10122249/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.