Technical guideFree to readYear not stated

PowerWalker VFI 10000 AT Single-Phase Online UPS

Original title PowerWalker VFI 10000 AT: 10122249

PowerWalker (BlueWalker GmbH)

PowerWalker VFI 10000 AT is a 10000 VA / 9000 W single-phase double-conversion tower UPS with 0.9 output power factor, 93% line-mode and 96% ECO-mode efficiency, 20 x 12 V 9 Ah batteries and a built-in maintenance bypass.

On this page

Overview

The product page presents the 10000 VA model (SKU 10122249) of the PowerWalker VFI AT series. The series is an online double-conversion UPS family for commercial applications, with wide input voltage and frequency ranges that allow operation on unstable networks. A built-in maintenance bypass switch (MBS), generator compatibility, EPO or ROO function, external battery connection (EBM), a configurable charger and an intelligent slot are standard. The series comes in 1000, 2000, 3000, 6000 and 10000 VA.

Technical data: 10000 VA / 9000 W, single-phase in and out (1-1), pure sine wave, output power factor 0.90, input power factor above 0.99 at full load, input voltage window 110-300 V AC at 40% load and 176-300 V AC at 100% load, nominal output 208/220/230/240 V AC, crest ratio 3:1, battery-mode frequency ±0.1 Hz. Full-load efficiency is 93% in line mode, 91% in battery mode and 96% in ECO mode. Transfers: line to battery 0 ms, to bypass 0 ms, to and from ECO mode 10 ms.

Batteries are 20 x 12 V / 9 Ah; the charger is adjustable at 1 A / 2 A / 4 A with 4 hours to 90%. Noise is below 55 dB and the operating temperature 0-40 °C. Product size is 412x196x702 mm at 75.5 kg; the package is 566x350x956 mm at 82 kg. Accessories include an AS400 card, SNMP card 2, IEC cables, input power cables, RS-232 and USB cables and the BP AT240T-40x9Ah external battery pack.

Key points

  1. 10000 VA / 9000 W, 1-1 phase, tower; output power factor 0.90; input power factor above 0.99.
  2. Input 110-300 V AC (40% load) and 176-300 V AC (100% load); output 208/220/230/240 V AC.
  3. Efficiency: 93% line mode, 91% battery mode, 96% ECO mode.
  4. Transfer: line mode to battery 0 ms; bypass 0 ms; to and from ECO 10 ms.
  5. Batteries 20 x 12 V / 9 Ah; charge current 1/2/4 A adjustable; 4 h to 90%.
  6. Size 412x196x702 mm; weight 75.5 kg (82 kg packed); noise below 55 dB; 0-40 °C.
  7. Built-in maintenance bypass, generator compatibility, EPO/ROO, external battery connector and management card slot.
  8. Accessories: SNMP card 2, AS400 card, BP AT240T-40x9Ah battery pack.

Using it in design

  • To balance a 9 kW single-phase load on a three-phase supply, set the phase assignment at design stage.
  • Check floor and layout for the 75.5 kg weight and 196x412 mm footprint.
  • Compare the 10 ms ECO transfer with load tolerance.
  • On generator-fed sites, use the wide 110-300 V AC input window and set the charge current.
  • Calculate the number of BP AT240T-40x9Ah external packs for the required autonomy.

Who should read it

Electrical designers and procurement engineers seeking mid-power single-phase online UPS.

Document contents

  1. General Features
  2. Input
  3. Output
  4. Technical Details
  5. Batteries and Autonomy
  6. Communication
  7. Logistics
  8. Accessories
  9. Downloads

Publication details

Authors
PowerWalker (BlueWalker GmbH)
Publisher
PowerWalker (BlueWalker GmbH)
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

PowerWalker (BlueWalker GmbH) PowerWalker VFI 10000 AT: 10122249. PowerWalker (BlueWalker GmbH). https://powerwalker.com/product/10122249/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.