Schaefer Power Supply: AC/DC UPS
Schaefer Elektronik
Schaefer Elektronik's UPS and customised power systems page lists modular switchmode DC and AC UPS solutions with 100 W-100 kW DC output and 200 VA-45 kVA AC output from 10-800 V DC input.
On this page
Overview
The page from German manufacturer Schaefer Elektronik GmbH presents uninterruptible power supply (UPS) and customised systems. Switchmode AC-DC power supplies or DC-DC converters can also be used for battery charging. Different modules can be arranged into a system providing DC output power or used with inverters for AC output power. The page covers DC UPS and AC UPS in one frame.
Technical data: single-phase input 115/230 V AC, 50-400 Hz; three-phase input 200/400/480 V AC, 50-400 Hz; DC input 10-800 V. DC output voltages are 5, 9, 12, 15, 24, 28, 48, 60, 110, 200, 220, 400, 600 and 800 V. AC output is 115/230 V single-phase or 200/400/480 V three-phase, with crystal-stabilised or programmable frequency. DC output power is 100 W-100 kW and AC output power 200 VA-45 kVA.
Listed features are robust design, high reliability, turnkey solution, constant current and voltage operation, industrial-grade components and customised systems. The page refers to markets such as defence, e-mobility, energy, industry, marine, oil and gas and rail; it is not data-centre focused, though it lists data centres under the power quality market.
Key points
- Single-phase input 115/230 V AC, 50-400 Hz; three-phase input 200/400/480 V AC, 50-400 Hz; DC input 10-800 V.
- DC output voltages: 5, 9, 12, 15, 24, 28, 48, 60, 110, 200, 220, 400, 600, 800 V.
- AC output: 115/230 V single-phase or 200/400/480 V three-phase; frequency crystal-stabilised or programmable.
- DC output power 100 W-100 kW; AC output power 200 VA-45 kVA.
- Modules can be arranged as a DC power system or with an inverter as an AC power system.
- AC-DC or DC-DC modules can also be used for battery charging.
- Constant current and constant voltage operation; industrial-grade components; customised systems.
Using it in design
- For auxiliary systems with DC distribution (such as 48, 110 or 220 V DC), match the required output voltage and power to the ranges on the page.
- The very wide DC input window (10-800 V) can be assessed for use combined with batteries or renewable sources.
- For critical loads needing a custom system (control, communication, industrial), set up a project specification and test plan with the manufacturer.
- For large data centre UPS, note that the page's AC capacity limit (45 kVA) is small; it suits auxiliary and control loads.
Who should read it
Electrical designers looking for customised UPS for auxiliary systems, DC power distribution and industrial critical loads.
Document contents
- UPS: DC UPS or AC UPS
- Technical data
- Features
- Customised system examples
Publication details
- Authors
- Schaefer Elektronik
- Publisher
- Schaefer Elektronik
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Schaefer Elektronik Schaefer Power Supply: AC/DC UPS. Schaefer Elektronik. https://www.schaeferpower.de/en/products/power-supply
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.