Huafu High Rate Battery: Product List
Original title Huafu High Rate Battery: product list
Huafu Energy Storage
Huafu's HRB high-rate lead-acid batteries for UPS, data centre and telecom come as 12 V blocks from 45 to 140 Ah (12 V 160 W to 12 V 500 W); the maker states a very long life per Eurobat and 30% higher power density than ordinary batteries.
On this page
Overview
The page is the High Rate Battery product list on Huafu Battery's website. The HRB series is presented as blocks made on a fully automatic line with automatic welding, through-the-partition welding and heat sealing for good consistency. It is stated to give high-power discharge, long float backup time and fast charging, and to suit data centres, UPS and IDC rooms. Main applications are telecom, UPS, data centre and emergency power.
Features are a very long life per the Eurobat classification, power density 30% higher than ordinary batteries, a special lead paste formula and additives to extend life, maximum charge efficiency and a wide power range for easy sizing. The list gives eight 12 V models: 12 V 160 W (45 Ah), 12 V 215 W (55 Ah), 12 V 250 W (70 Ah), 12 V 300 W (80 Ah), 12 V 350 W (90 Ah), 12 V 400 W (105 Ah), 12 V 450 W (120 Ah) and 12 V 500 W (140 Ah). The 12 V 160 W model is designed for 300-1500 VA small office, security and network UPS systems.
The page does not state the duration and end voltage behind the watt values, nor dimensions and weights; these are on each model's own page. The maker states 7-15 day delivery, OEM customisation and technical support.
Key points
- The HRB series is a 12 V high-rate lead-acid block range; applications are telecom, UPS, data centre and emergency power.
- Eight models: 160 W (45 Ah), 215 W (55 Ah), 250 W (70 Ah), 300 W (80 Ah), 350 W (90 Ah), 400 W (105 Ah), 450 W (120 Ah), 500 W (140 Ah).
- The 12 V 160 W model is designed for 300-1500 VA small office, security and network UPS systems.
- Very long life per Eurobat classification; 30% higher power density than ordinary batteries.
- Fully automatic production with automatic welding, through-the-partition welding and heat sealing.
- Delivery 7-15 days; OEM customisation available.
Using it in design
- Confirm on each model page the duration and end voltage behind the watt value before using it in UPS autonomy sizing.
- Match the 12 V 160 W model to small UPS (300-1500 VA) and the 250-500 W models to larger battery banks by capacity step.
- Attach the model datasheet with dimension, weight and discharge tables to the specification.
Who should read it
Electrical designers and procurement teams sourcing high-rate batteries for UPS.
Document contents
- Main applications
- Brief of high rate battery
- Features and benefits
- 12 V product list
- Brand promise
Publication details
- Authors
- Huafu Energy Storage
- Publisher
- Huafu Energy Storage
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Huafu Energy Storage Huafu High Rate Battery: product list. Huafu Energy Storage. https://www.huafubattery.com/products.php?id=19&fid=1
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.