MCA General Purpose AGM Battery FC Series: Specifications Table
Original title MCA General Purpose AGM Battery FC Series: Specifications table
MCA Battery
The MCA FC series is a general-purpose, high-rate AGM VRLA range in 6 V and 12 V, from 4 to 250 Ah, with a 10-year float design life at 25 °C and CE, UL and ISO certification.
On this page
Overview
The MCA FC series comprises valve-regulated AGM batteries for UPS, telecom backup, lighting, fire alarm and security systems and solar storage. The product page gives rated voltage as 12 V and 6 V, capacity from 4 to 250 Ah and a float-charge design life of 10 years at 25 °C; certificates are CE, UL, ISO 9001, ISO 14001 and ISO 45001.
The manufacturer states that the AGM design immobilizes the electrolyte to prevent leaks, that sealed construction needs no water refilling and that tightly packed plates resist vibration. Self-discharge is at most 3% per month and operating temperature is -20 to 50 °C. Low internal resistance gives fast energy release, which is why the range is aimed at high-discharge uses such as UPS, telecom backup and solar storage.
The specification table lists, for 12 V models from FC12-4 to FC12-250ZT and 6 V models from FC6-130AT to FC6-200BT, each model's capacity (at the 20-hour rate for the small models and at the 10-hour rate from 24 Ah up), length, width and height, weight (±3%), terminal type and screw size. For example, FC12-100RT is 100 Ah, 331 x 174 x 214 mm and 28.7 kg. Electrical curves and runtimes are not on the page.
Key points
- Nominal voltage 12 V and 6 V; capacity 4 to 250 Ah.
- Float design life 10 years at 25 °C; certificates CE, UL, ISO 9001, ISO 14001, ISO 45001.
- Self-discharge at most 3% per month; operating range -20 to 50 °C.
- Capacity rate: 20-hour for models of 4 to 20 Ah, 10-hour from 24 Ah up.
- FC12-100RT: 100 Ah, 331 x 174 x 214 mm, 28.7 kg, terminal T4-M8.
- FC12-250ZT: 250 Ah, 520 x 268 x 220 mm, 70 kg.
- 6 V models: FC6-130AT (130 Ah, 20.5 kg) to FC6-200BT (200 Ah, 29.5 kg).
- Terminal types F1/F2, L1 to L4, T1 to T5; screws M5, M6, M8.
Using it in design
- Calculate string size and rack from the table's length, width and height and the ±3% weight tolerance.
- Note that the capacity rate is 20-hour or 10-hour, giving different capacity references in runtime calculations.
- Design life applies at 25 °C; keep the battery room close to that temperature.
- Select cable and busbar termination detail by the model's terminal type.
- For high-current UPS duty, request discharge curves from the manufacturer separately.
Who should read it
Electrical engineers and buyers selecting battery systems for small and mid-size UPS installations.
Document contents
- Product overview
- Features
- Applications
- Specifications (model, voltage, capacity, dimensions, weight, terminal)
- Related products
Publication details
- Authors
- MCA Battery
- Publisher
- MCA Battery
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
MCA Battery MCA General Purpose AGM Battery FC Series: Specifications table. MCA Battery. https://www.mcabattery.com/ProductDetail/1.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.