SSB Battery SBL-HR Xtreme high-rate AGM battery series (for UPS)

Original title SSB Battery SBL-HR Xtreme product table

SSB Battery

SSB Battery SBL-HR Xtreme is a series of sealed, maintenance-free 12 V AGM batteries for UPS and diesel start-up systems: 26-220 Ah (C10), 118-827 W for 15 minutes, over 12 years life per EUROBAT.

On this page

Overview

The page contains the product overview of Germany-based SSB Battery and the model table of the SBL-HR Xtreme series. SSB offers the SB/SBL, SBH, SBL-HR Xtreme, Grid Power and PLP series, covering high-current UPS applications with short discharge times as well as emergency lighting with long autonomy.

The SBL-HR Xtreme series is sealed, completely maintenance-free lead-acid AGM (Absorbent Glass Mat) batteries. HR stands for High Rate, meaning high discharge current within a very short time. The manufacturer states 30% more high-current performance and up to 35% less space than its previous SBL-HR series. Service life is over 12 years ('Very Long Life' per EUROBAT) and every model has a V0 flame-retardant plastic case per UL94.

The model table lists 12 V monoblocs in nine sizes: SBL120-12HR (26 Ah, 118 W/15 min), SBL150 (33 Ah, 152 W), SBL200 (55 Ah, 204 W), SBL330 (75 Ah, 327 W), SBL410 (90 Ah, 412 W), SBL440 (100 Ah, 437 W), SBL560 (140 Ah, 564 W), SBL730 (192 Ah, 730 W) and SBL830 (220 Ah, 827 W). Power values are for a 15-minute discharge to 1.6 V per cell, and capacities are given at C10.

Weights run from 9.6 kg to 67.5 kg; for example the 26 Ah model measures 165x125x175 mm and weighs 9.6 kg, and the 220 Ah model 522x238x223 mm and 67.5 kg. Terminals are F-M5, F-M6 and F-M8. Applications are UPS, electrical power supply systems (EPS), emergency power, emergency lighting, railway signalling, alarm and security systems, communication and DC power supplies.

Key points

  1. Series: sealed, maintenance-free AGM, 12 V; nine models, 26-220 Ah (C10).
  2. 15 min, 1.6 V/cell power: 118, 152, 204, 327, 412, 437, 564, 730 and 827 W.
  3. Service life over 12 years per EUROBAT (Very Long Life).
  4. 30% more high-current performance and up to 35% less space than the previous SBL-HR (manufacturer's claim).
  5. V0 flame-retardant plastic case per UL94.
  6. Weight from 9.6 kg (26 Ah) to 67.5 kg (220 Ah).
  7. Largest model 522x238x223 mm; terminals F-M5, F-M6, F-M8.
  8. Applications: UPS, EPS, emergency power, emergency lighting, railway signalling, communication.

Using it in design

  • In UPS battery selection use the 15-minute W per cell figure rather than C10 capacity, and divide the UPS DC power need by the cell count to choose the model.
  • Calculate rack and floor loading from the model weights (9.6-67.5 kg per block) and dimensions.
  • Note that the over-12-years figure is an EUROBAT class; real life depends on temperature and charging, so ask the manufacturer for the life correction curve for the battery room temperature.
  • Add the F-M5/M6/M8 terminal type to the cable and busbar compatibility list.
  • Match the V0 case fire class to the battery room fire specification.

Who should read it

Electrical designers sizing UPS battery systems, engineers selecting diesel start batteries and procurement teams evaluating battery suppliers.

Document contents

  1. SSB Battery product overview
  2. SBL-HR Xtreme series description
  3. Areas of application
  4. Model table (SBL120-12HR to SBL830-12HR)

Publication details

Authors
SSB Battery
Publisher
SSB Battery
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

SSB Battery SSB Battery SBL-HR Xtreme product table. SSB Battery. https://ssb-battery.com/en/products-sblxtreme-en/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.