OMRON BU_2SW and BU_2RWL Series Online UPS Leaflet
Original title OMRON BU_2SW and BU_2RWL UPS leaflet, specifications p.3
OMRON
OMRON leaflet for 1-5 kVA single-phase online UPS: tower BU_2SW (1000 and 3000 VA) and 19-inch rack BU_2RWL (2000, 3000 and 5000 VA), with hot-swappable batteries and backup time tables.
On this page
Overview
The leaflet presents a single-phase double-conversion OMRON UPS family in two form factors. The BU_2SW is a tower: BU1002SWG 1000 VA / 700 W and BU3002SWG 3000 VA / 2100 W. The BU_2RWL is a 19-inch rack type: BU2002RWLG 2000 VA / 1400 W, BU3002RWLG 3000 VA / 2100 W and BU5002RWLG 5000 VA / 3500 W. Target uses are industrial PCs, vision systems and controllers; the output is pure sine and the system shuts down safely while data is saved.
Input is 220/230/240 V AC (200-240 V options for the BU_2RWL) and output voltage accuracy is ±2% to ±3% by mode. The tower uses a Schuko input plug with IEC C13 and terminal outputs; the rack types offer C19/C13, NEMA L6-30R and terminal blocks. Batteries are sealed lead-acid, with expected life of 4-5 years at 20 °C for the BU_2SW and 5 years at 25 °C for the BU_2RWL. Operating environment is 0-40 °C and 25-85% RH non-condensing.
The document lists order codes, replacement batteries (12 V 7.2 Ah and 9 Ah, 48 V 9 Ah, 72 V 9 Ah), mounting bracket and communication cards (SC08G I/O signal, SC20G2 SNMP/Web). Backup times in minutes are given for loads from 20 W to 3500 W; for example the BU3002SWG gives 170 minutes at 100 W and 5 minutes at 2100 W, and the BU5002RWLG gives 5 minutes at 3500 W.
Key points
- BU_2SW (tower): 1000 VA / 700 W and 3000 VA / 2100 W; BU_2RWL (19-inch rack): 2000 VA / 1400 W, 3000 VA / 2100 W and 5000 VA / 3500 W.
- Output voltage ±2% to ±3% in 200-240 V modes, pure sine; the BU_2RWL also has a 100 V mode.
- BU3002SWG backup: 170 min at 100 W, 15 min at 1000 W, 5 min at 2100 W.
- BU5002RWLG backup: 320 min at 100 W, 39 min at 1000 W, 5 min at 3500 W.
- Hot-swappable batteries; sealed lead-acid with expected life of 4-5 years.
- Size: BU1002SWG 145x395x224 mm, 15.5 kg; BU3002SWG 213x537x432 mm, 35 kg; rack types 2U and 3U, 28-61 kg.
- Communication: RS-232C, USB (BU_2SW), I/O signal; optional SNMP/Web card SC20G2.
- Safety: CE/RoHS for BU_2SW; UL1778/CE/RoHS for BU_2RWL; operation 0-40 °C.
Using it in design
- For in-rack use, compare the 2U and 3U heights and 28-61 kg weights with the rack load rating.
- Read autonomy from the backup table and allow for the steep drop in time as load rises (for example from 1000 W to 2000 W).
- Plan service intervals around the 4-5 year battery life, using hot-swap replacement.
- Add the SC20G2 SNMP/Web card or SC08G I/O card to the specification for monitoring.
- In edge and small IT rooms, place units with the 0-40 °C limit and the link between ambient temperature and battery life in mind.
Who should read it
Designers selecting single-phase UPS for edge sites, industrial PCs and small IT rooms.
Document contents
- How you benefit
- Ordering information
- Specifications
- Backup time table
Publication details
- Authors
- OMRON
- Publisher
- OMRON
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
OMRON OMRON BU_2SW and BU_2RWL UPS leaflet, specifications p.3. OMRON. https://files.omron.eu/downloads/latest/brochure/en/ups_leaflet_en.pdf