ENAG's ALMIV is a Bureau Veritas type-approved double-conversion AC/AC UPS family for marine and mobile use: 14 models from 500 VA to 20 kVA with 10, 30 or 60 minutes of back-up.

On this page

Overview

ENAG's FC-ALMIV-EN-D leaflet presents the ALMIV range of AC/AC UPS units designed to operate aboard ships, vehicles and mobile engines of all types. The units are double-conversion, built from a charger/rectifier and an inverter, with the battery that provides autonomy either integrated or external. The standard range is covered by Bureau Veritas type approval certificate no. 07671, and conformity with BV, DNV, LR and ABS regulations is stated.

The standard table lists 14 models: ALMIV-500, 700, 900, 1200, 1500, 2000, 2600, 3500, 5000, 7500, 10000, 12500, 15000 and 20000. Apparent power runs from 500 VA to 20 000 VA and active power is tabulated separately (for example 350 W for 500 VA, 4 000 W for 5 000 VA, 16 000 W for 20 000 VA). Back-up time is 10, 30 or 60 minutes for every model. Input and output voltages are 115, 230, 400, 440 or 690 V, single- or three-phase according to model.

Main specifications: input tolerance +/-10% and frequency 50-60 Hz +/-5%; output voltage regulation +/-2%, frequency 50 or 60 Hz +/-0.01% and harmonic distortion 3%; automatic static bypass on overload or equipment fault; and efficiency at nominal power of 82% to 92% by model (up to 20 kVA). The cabinet is metal with IP23 protection, operating temperature is 0 to +45 C and humidity is at most 95% non-condensing; installation and wiring are arranged to attenuate shock and vibration, and windings are tropicalized.

The leaflet is not contractual and asks users to consult ENAG before installation. Dimensions and weight are not published, and because voltage, phase count and back-up time are configurable no single voltage, runtime or efficiency is assigned. Other voltages, frequencies, powers up to 300 kVA and options (improved power factor, EMI filter, dry contacts, DC emergency input) are available on request.

Key points

  1. 14 standard models from 500 VA to 20 000 VA; active power is tabulated (500 VA/350 W, 1 500 VA/1 050 W, 5 000 VA/4 000 W, 20 000 VA/16 000 W).
  2. Back-up time is 10, 30 or 60 minutes for every model, using sealed lead batteries; other times on request.
  3. Input/output voltage is 115, 230, 400, 440 or 690 V, single- or three-phase by model.
  4. Input tolerance +/-10%; output regulation +/-2%; output frequency 50 or 60 Hz +/-0.01%; harmonic distortion 3%.
  5. Efficiency at nominal power is 82-92% by model (up to 20 kVA); automatic static bypass on overload or fault.
  6. BV type approval (no. 07671); conformity with BV, DNV, LR and ABS regulations; classification-society inspection on request.
  7. Protection class IP23; operating temperature 0 to +45 C; humidity at most 95% non-condensing; anti-corrosion treatment and tropicalizing varnish.
  8. Options: improved power factor, EMI filter, dry contacts, DC emergency input; special ratings up to 300 kVA.

Using it in design

  • For marine and mobile projects, match the classification society (BV, DNV, LR, ABS) requirement to the unit's type approval.
  • Size the load against the tabulated active power (W) rather than apparent power; for example the 5 000 VA model delivers 4 000 W.
  • Choose the back-up time (10, 30, 60 min) and battery type from the project load profile; ask the manufacturer for other times.
  • Compare the 0-45 C ambient limit and IP23 rating with machinery-space conditions.
  • Dimensions and weight are not in the leaflet; request model-specific drawings for layout.

Who should read it

Electrical engineers designing protected AC supplies on ships, mobile machinery and industrial installations.

Document contents

  1. Standard range with BV certificate
  2. Main technical specification (input, output, protections, back-up, presentation, environment, certification, options)

Publication details

Authors
ENAG
Publisher
ENAG
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ENAG ENAG FC-ALMIV-EN-D, standard model table p.1. ENAG. https://www.enag.fr/english/fc-alimv-en-d/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.