Champion 6FM90 High Rate 12V90Ah: named-product description
Champion Battery
A product page from Champion Storage Battery for the 6FM90 sealed lead-acid battery for UPS, inverter and renewable-energy use: 12 V, 90 Ah nominal capacity, a 307 x 168 x 211 mm case (215 mm total height) and 26 kg.
On this page
Overview
The page presents the 12 V 90 Ah product in the high-rate battery category of Shenzhen-based Champion Storage Battery Company. The product panel names the model 6FM90 and gives its origin as Guangdong, China. The battery is sealed and maintenance-free, has an ABS cover and is recommended for telecom, UPS and power systems. The panel also states OEM/ODM service, a production time of 20 to 25 days and case colour options of black, blue, grey or green.
The features section describes the battery as completely sealed, needing no water and releasing no acid gas. The text refers to gel (colloid) electrolyte technology, which prevents stratification of acid density and the plate corrosion that follows from it. For the 12 V series, design life is given as up to 10 years in float service at an ambient temperature of 20 to 25 °C. The manufacturer states that, because of the larger electrolyte volume, the gel construction works more stably than an AGM battery at high temperature or under overcharge.
The application list covers line-interactive UPSs, DC power systems, hybrid UPSs, on-grid and off-grid power, solar and wind storage, signalling and emergency lighting. Lower on the page is a general table for the whole 6FM family: dimensions, terminal type and weight with a ±3% tolerance for 12 V models from 5.5 Ah to 250 Ah. In the 90 Ah class that table lists several variants, such as 6FM90E, 6FM90A, 6FM90B and 6FM90S.
The page does not state the discharge duration (C10 or C20) or the end voltage at which capacity is defined. It also has no constant-power discharge tables, internal resistance, short-circuit current, charging voltage or temperature correction data. The page is therefore sufficient to establish the product's identity, size and weight; a UPS runtime calculation needs the manufacturer's detailed datasheet.
Key points
- Model 6FM90: 12 V, 90 Ah nominal, sealed maintenance-free lead-acid.
- Dimensions 307 x 168 x 211 mm, total height 215 mm; weight 26 kg.
- Cover material ABS; origin Guangdong, China.
- Design life of the 12 V series is up to 10 years in float service at 20...25 °C.
- The features text describes gel (colloid) electrolyte technology.
- The family table spans 12 V models from 5.5 Ah to 250 Ah; weight tolerance ±3%.
- 90 Ah class variants in the family table: 6FM90E (306 x 169 x 211 mm, 26.5 kg), 6FM90A (330 x 171 x 214 mm), 6FM90S (406 x 173 x 208 mm, 28 kg).
- Production time 20...25 days; OEM/ODM service is offered.
Using it in design
- Use 307 x 168 x 215 mm and 26 kg per block for battery cabinet layout.
- Before a UPS runtime calculation, request the constant-power (W/cell) discharge table and the discharge duration at which capacity is defined.
- Distinguish 6FM90 from the 6FM90E, 6FM90A, 6FM90B and 6FM90S variants when ordering; their dimensions and weights differ.
- Reflect in the battery-room temperature design that the 10-year design life applies at 20...25 °C.
- Have the manufacturer confirm the electrolyte type in writing so charger settings can be chosen for gel or AGM construction.
Who should read it
Electrical designers selecting UPS battery strings, engineers laying out battery cabinets, and procurement teams.
Document contents
- High Rate Discharge Battery Description
- High Rate Discharge Battery Features
- High Rate Discharge Battery Applications
- High Rate Discharge Battery Specifications
- Competitive Advantage
Publication details
- Authors
- Champion Battery
- Publisher
- Champion Battery
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Champion Battery Champion 6FM90 High Rate 12V90Ah: named-product description. Champion Battery. https://c-battery.com.cn/High-Rate-Battery-12v90ah-For-UPS-Inverter-Solar-Power-wind-power-p6463105.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.