Power Kingdom High Rate Series: model parameters

Original title Power Kingdom High Rate Series: Model Parameters

Power Kingdom

Model table for the Power Kingdom High Rate series of 6 V and 12 V VRLA batteries: 4.5 to 250 Ah range, 10-year design life, 15-minute rated power from 60 W to 4440 W, plus dimension and terminal data.

On this page

Overview

The page presents the high-rate VRLA series from Power Kingdom, a battery maker since 1957. The series is designed to provide the constant power backup that UPS systems and critical backup applications require; startup standby power supply systems and electric tools are among the stated uses. Nominal voltage is 6 V and 12 V, capacity ranges from 4.5 Ah to 250 Ah, and design life is 10 years.

Main features include valve-regulated, maintenance-free, spill-proof construction, high energy density, a high rate of charge and discharge, special lead-calcium alloy plates with high-purity additive, and rugged impact-resistant, flame-retardant ABS cases. Typical applications are electric power equipment, UPS equipment, electric tools and medical devices.

The model table gives, for each battery, the 15-minute rated power, rated capacity (Ah), length, width, height and total height (mm) and terminal type. It starts with PS4.5P-6 (60 W, 5 Ah, 70 x 47 x 100 mm) and ends with PK200P-12B (4440 W, 200 Ah, 522 x 238 x 218 mm); some models have X-suffixed variants with a different terminal type. The table does not assign voltage to individual models; voltage is read from the family's 6 V and 12 V declaration.

Key points

  1. Series: High Rate VRLA; nominal voltage 6 V and 12 V; capacity 4.5 to 250 Ah; design life 10 years.
  2. 15-minute rated power runs from 60 W (PS4.5P-6) to 4440 W (PK200P-12B).
  3. Example models: PS7P-12B 156 W / 7.5 Ah / 151 x 65 x 94 mm; PK100P-12B 2220 W / 105 Ah / 328 x 172 x 217 mm; PK150P-12B 3330 W / 150 Ah / 485 x 169 x 240 mm.
  4. Terminal types are listed as T1/T2, T2, T3, T4, T5, T6, T8, T9, T10, T11, T12 and T13.
  5. ABS case, flame retardant; valve-regulated, spill-proof and maintenance-free construction.
  6. Applications: electric power equipment, UPS equipment, electric tools, medical devices.

Using it in design

  • Compare the 15-minute power needed for the UPS load with the model's W value in the table to set the number of blocks.
  • Check length, width and total height of each model against rack internal dimensions.
  • Match the terminal type with the UPS battery connection cable and busbar design.
  • Re-evaluate the 10-year design life against ambient temperature and operating conditions.

Who should read it

Electrical designers selecting UPS battery strings and teams preparing battery comparison data.

Publication details

Authors
Power Kingdom
Publisher
Power Kingdom
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Power Kingdom Power Kingdom High Rate Series: Model Parameters. Power Kingdom. https://www.powerkingdom.com.cn/products_detail/High_Rate_Series.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.