Saite Power High Rate Series: Model Specification Table

Original title Saite Power High Rate Series: model specification table

Saite Power Source (Vietnam)

Saite Power Source (Vietnam) High Rate series of 12 V AGM monoblocs: 4 to 250 Ah, 15-minute watt ratings, self-discharge of 3 percent per month or less, and a 5 to 8 year design life.

On this page

Overview

The document is the product page for the High Rate battery series from Saite Power Source in Vietnam. The series consists of 12 V monoblocs designed for good performance in high-current discharge and for applications that need high-rate discharge, such as UPS and EPS. The stated features are a capacity range of 4 to 250 Ah, self-discharge of 3 percent per month or less, oxygen recombination efficiency of 98 percent or more, a design lifetime of 5 to 8 years in standby use at 25 °C and an operating temperature range of 0 to 40 °C.

For each model the product table gives the 15-minute power rating (for example 12 V 21 W@15 min or 12 V 850 W@15 min), nominal voltage, capacity, length, width, height and total height, weight and terminal type. Models are listed with an HR prefix: HR-21W is 5.5 Ah and 1.66 kg, and HR-850W is 275 Ah and 75.9 kg. The table also has separate rows for the BT-HSE and BT-FT (front terminal) families.

High-rate blocks are optimized for shorter, higher-power discharge than standard blocks of the same capacity, so UPS battery selection is usually made on the 15-minute watt rating rather than Ah. Because the table does not say which discharge time the Ah column refers to or whether the 15-minute watt figure is per cell or per block, power or energy should not be calculated directly from these values; the manufacturer's discharge table should be used.

The page contains the model table and general features; it does not include discharge curves, float voltage or a standards declaration.

Key points

  1. 12 V high-rate AGM monobloc series; capacity range 4 to 250 Ah.
  2. Self-discharge of 3 percent per month or less; oxygen recombination efficiency of 98 percent or more.
  3. 5 to 8 year design life in standby use at 25 °C; operating temperature 0 to 40 °C.
  4. Power rating is on a 15-minute basis: HR-21W is 12 V 21 W@15 min, HR-850W is 12 V 850 W@15 min.
  5. HR-21W: 5.5 Ah, 91 × 70 × 102 mm (total height 107 mm), 1.66 kg, terminal F02.
  6. HR-850W: 275 Ah, 520 × 268 × 220 mm (total height 224 mm), 75.9 kg, terminal T65.
  7. Dimensions are given with a ±2 percent weight tolerance and a terminal type per model.
  8. The series includes BT-HSE and BT-FT (front terminal) sub-families.

Using it in design

  • When selecting a UPS battery bank, compare the model's 15-minute watt rating with the UPS's required power per cell or per block, and confirm with the manufacturer whether the basis is cell or block.
  • Do not calculate autonomy from Ah without confirming the discharge time and end voltage behind the Ah column.
  • Use length, width, total height and weight for rack layout, and check floor loading for the tall models.
  • Determine connector and torque requirements from the terminal type.
  • Reflect the design life (5 to 8 years at 25 °C) and ambient temperature in the battery replacement plan.

Who should read it

Electrical designers sizing UPS battery banks and procurement teams selecting batteries.

Document contents

  1. Features
  2. Model specification table: 15-minute rate, voltage, capacity, dimensions, weight, terminal type

Publication details

Authors
Saite Power Source (Vietnam)
Publisher
Saite Power Source (Vietnam)
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Saite Power Source (Vietnam) Saite Power High Rate Series: model specification table. Saite Power Source (Vietnam). https://www.saitebatterysupply.com/Products_details/16.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.