MCM Linha Action 1800VA 3.1 UPS0258 technical specifications
MCM
MCM Action UPS0258 is a small UPS with 1170 W peak nominal power, trivolt (115/127/220 Vac) input, 115 Vac output, approximated sine (PWM) battery output, 2 x 12 V internal batteries and a weight of 13 kg.
On this page
Overview
The Brazilian manufacturer MCM's product page presents the Action line 1800VA 3.1 model (UPS0258). The unit is a small line-interactive-style backup with mains voltage regulation; its battery-mode output waveform is listed as approximated sine (rectangular PWM). The page highlights a 2-year warranty, nine protection levels and trivolt input (115/127/220 Vac); output is 115 Vac.
Power is printed as 1170 W (nominal peak); no continuous power value is given. Input under- and over-voltage protection and a mains stabiliser function are included. The internal battery count is 2 units of 12 V; an external 12 Vdc battery can be connected and the unit has a runtime-extension terminal (an MBA Overtime or an external battery can be attached). Automatic restart, 6 outlets, an LED indicator and an audible alarm on mains loss are provided.
Dimensions are 130.5 x 193.7 x 388.7 mm (W x H x D) and weight is 13.0 kg. Specifications may change without notice. The page does not state runtime with an external battery; runtime must be calculated for the user's load and the battery to be connected.
Key points
- Power 1170 W, printed as nominal peak; continuous power not stated.
- Input 115/127/220 Vac (trivolt); output 115 Vac.
- Approximated sine (rectangular PWM) output in battery mode.
- 2 x 12 V internal batteries; terminal for an external 12 Vdc battery and the MBA Overtime.
- Input under- and over-voltage protection; mains stabiliser function; automatic restart.
- 6 outlets; LED indicator; audible alarm on mains loss.
- Size 130.5 x 193.7 x 388.7 mm (W x H x D); weight 13.0 kg.
- 2-year warranty.
Using it in design
- Treat the 1170 W figure as a peak value and keep the continuous load power below it.
- Check approximated-sine battery mode for compatibility with loads that have active-PFC power supplies.
- Runtime with an external battery is not on the page; calculate it yourself from battery capacity.
- When choosing 115, 127 or 220 Vac input, note that output stays at 115 Vac in every case.
- Classify it for non-critical loads such as small offices, network or retail endpoints.
Who should read it
Buyers and IT managers seeking a small nobreak on the Brazilian market.
Document contents
- Product summary
- Technical specifications
Publication details
- Authors
- MCM
- Publisher
- MCM
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
MCM MCM Linha Action 1800VA 3.1 UPS0258 technical specifications. MCM. https://mcmfontesenobreaks.ind.br/produtos/ups0258/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.