Dotvolt VoltEX TR 10–80 kVA 3/3: CE Declaration of Conformity
Dotvolt; hosted by Altay EMS
A one-page CE declaration of conformity dated 10 January 2024 in which Dotvolt Elektrik Elektronik Enerji San. Tic. A.Ş. declares that its VoltEX TR 10, 20, 30, 40, 60 and 80 kVA 3/3 UPS models comply with the Low Voltage Directive 2014/35/EU and the EMC Directive 2014/30/EU.
On this page
Overview
The document is a CE declaration of conformity issued under the manufacturer's sole responsibility and hosted on the Altay EMS website. The declaring company is Dotvolt Elektrik Elektronik Enerji San. Tic. A.Ş., with an address in Kartal, Istanbul; the product type is UPS (uninterruptible power supply) and the trade mark is DOTVOLT. The models in scope are listed individually: VoltEX TR 10 kVA 3/3, 20 kVA 3/3, 30 kVA 3/3, 40 kVA 3/3, 60 kVA 3/3 and 80 kVA 3/3. All six are three-phase in, three-phase out.
The declaration rests on two European Union directives: the Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility Directive 2014/30/EU. On the safety side the applied standard is EN IEC 62040-1:2019+A1:2021. On the EMC side it cites EN 62040-2:2018 together with EN 61000-3-12:2011, which limits harmonic currents injected into the supply, and EN 61000-3-11:2019, which limits voltage fluctuation and flicker. It was signed in Istanbul on 10 January 2024 by the general coordinator.
A declaration of conformity is not a performance document: it carries no power, efficiency, battery or dimension data, which are found in the series datasheets. Its role in design is to put on file the identity of the brand and of the legal entity responsible for the declaration, the list of covered models and the editions of the applied standards. The EMC category under EN 62040-2 is not stated in the declaration; the Volt EX datasheets give Category C3. Where a specification asks for CE marking and a standard edition, this declaration is the direct evidence.
Key points
- Declaring company: Dotvolt Elektrik Elektronik Enerji San. Tic. A.Ş., Kartal/Istanbul; trade mark DOTVOLT.
- Models covered: VoltEX TR 10, 20, 30, 40, 60 and 80 kVA, all 3/3.
- Directives: Low Voltage 2014/35/EU and EMC 2014/30/EU.
- Safety standard: EN IEC 62040-1:2019+A1:2021.
- EMC standards: EN 62040-2:2018, EN 61000-3-12:2011 and EN 61000-3-11:2019.
- Date and place of signature: 10 January 2024, Istanbul.
Using it in design
- Where the specification requires CE conformity, check that the offered model is one of the six in the declaration; models of 100 kVA and above are outside its scope.
- Copy the standard editions from the declaration (EN IEC 62040-1:2019+A1:2021, EN 62040-2:2018) into the compliance file and compare them with the editions the project requires.
- Use the EN 61000-3-12 and EN 61000-3-11 references in the grid-connection assessment for harmonic and flicker limits.
- Take electrical sizing data from the relevant Volt EX datasheet, not from this declaration, which documents conformity identity only.
Who should read it
Project engineers compiling compliance files, quality teams auditing CE and standards requirements and procurement specialists confirming supplier identity.
Document contents
- Declaring company and address
- Type, trade mark and models
- EC directives
- LVD standards
- EMC standards
- Signature and date
Publication details
- Authors
- Dotvolt; hosted by Altay EMS
- Publisher
- Dotvolt; hosted by Altay EMS
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Dotvolt; hosted by Altay EMS Dotvolt VoltEX TR 10–80 kVA 3/3: CE Declaration of Conformity. Dotvolt; hosted by Altay EMS. https://www.altayems.com/wp-content/uploads/2025/08/10-20-30-40-60-80.pdf