AllGrand 6-GFMHR high-rate battery: official preliminary brochure table

AllGrand

AllGrand's product page lists ten models of the 12 V high-rate 6-GFMHR battery series for UPS and switchgear: 10-hour capacity from 37 Ah to 210 Ah, a 12-year design life and internal resistance from 9.2 mΩ down to 2.3 mΩ; the manufacturer states that the figures are preliminary and that final configuration is confirmed in the quotation.

On this page

Overview

The page presents a series of 12 V (6 cell) batteries designed for UPS and switchgear duties that have to ride through short, heavy discharges. The battery type is given as VRLA gel (AGM). Model names carry a power class from 145 W to 750 W: 6-GFMHR-145W, 180W, 215W, 250W, 300W, 400W, 500W, 600W, 700W and 750W. Design life is 12 years. Charging voltage is 14.28 to 14.52 V for cycle use and 13.38 to 13.62 V for standby (float) use.

The model table gives 10-hour and 1-hour capacity, internal resistance and dimensions for each block. The smallest model, the 6-GFMHR-145W, is 37 Ah (10 hour), 20.4 Ah (1 hour), 9.2 mΩ and 197 x 166 x 174 mm. The largest, the 6-GFMHR-750W, is 210 Ah, 116 Ah, 2.3 mΩ and 523 x 239 x 220 mm. Block weights and constant-power discharge curves are not in the table; they are in the model-specific datasheet and are obtained from the manufacturer at quotation stage.

The page names the typical uses as UPS and data-centre backup, switchgear and emergency control, and short-duration high-current duty. Three inputs are to be settled before quotation: backup duration and discharge current, the end voltage required by the UPS or system, and the cabinet, rack and terminal configuration. The manufacturer states that the figures come from the current brochure, are indicative and may be revised without notice. Company certifications are ISO 9001, ISO 14001 and ISO 45001.

Key points

  1. Ten models: 6-GFMHR-145W, 180W, 215W, 250W, 300W, 400W, 500W, 600W, 700W and 750W; nominal voltage 12 V (6 cells).
  2. 10-hour capacities in order: 37, 45, 55, 65, 75, 100, 125, 150, 180 and 210 Ah.
  3. 1-hour capacities in order: 20.4, 24.8, 30.25, 35.8, 42.3, 55, 68.8, 82.5, 99 and 116 Ah.
  4. Internal resistance runs from 9.2 mΩ (145W) to 2.3 mΩ (750W); 3.5 mΩ on the 400W model.
  5. Sample dimensions: 145W 197 x 166 x 174 mm, 400W 408 x 174 x 210 mm, 750W 523 x 239 x 220 mm.
  6. Design life 12 years; battery type VRLA gel (AGM).
  7. Charging voltage: 14.28 to 14.52 V for cycle use, 13.38 to 13.62 V for standby use (per block).

Using it in design

  • When sizing a UPS battery string, ask the manufacturer for the model-specific constant-power discharge table (W per cell against end voltage); the Ah values on the product page serve for preselection only.
  • Set the UPS rectifier float voltage within 13.38 to 13.62 V per block and confirm temperature compensation from manufacturer data.
  • Use the tabulated internal resistance values for battery short-circuit current and battery breaker selection.
  • Lay out racks or cabinets from the block dimensions in the table, and obtain block weight with the quotation for floor loading.
  • Assess the 12-year design life together with battery room temperature and write the replacement interval into the operating budget.

Who should read it

Electrical engineers sizing UPS battery strings, procurement teams sourcing batteries, and teams preparing product catalogue data.

Document contents

  1. Model overview
  2. Overview
  3. Key features
  4. Specification
  5. Applications & selection
  6. Gallery
  7. Downloads

Publication details

Authors
AllGrand
Publisher
AllGrand
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

AllGrand AllGrand 6-GFMHR high-rate battery: official preliminary brochure table. AllGrand. https://allgrand.com/products/high-rate-battery-6-gfmhr-12v

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.