Dongjin SLA Rechargeable Battery: model specification table

Dongjin Power

A Dongjin Power product page with the model list of its DJ series AGM sealed lead-acid (SLA/VRLA) batteries: 71 rows at 6 V and 12 V, capacities from 0.8 to 300 Ah at the 10-hour rate, dimensions, terminal type and weights from 0.33 to 72 kg.

On this page

Overview

The page sits in the UPS battery category of the lead-acid range of Shenzhen-based Dongjin Power Co., Ltd. The product is a maintenance-free sealed lead-acid battery with AGM (absorbent glass mat) technology; the page refers to the same product as SLA, AGM and VRLA. The feature list is short: maintenance-free operation, AGM technology, CE recognition and an ABS container. Applications named are power storage, UPS systems, alarms and electrical devices.

Each row of the model list gives the model name, voltage, 10-hour (10Hr) capacity, length, width, height and total height in millimetres, terminal type and weight in kilograms. The table has 71 rows. Small 6 V models run from DJ6-4 (4 Ah, 0.68 kg) to DJ6-14 (14 Ah); large 6 V blocks run from DJ6-100 to DJ6-300 (300 Ah, 295 x 178 x 345 mm, 46 kg). The 12 V models run from DJ12-0.8 (0.8 Ah, 0.33 kg) to DJ12-260 (260 Ah, 520 x 269 x 220 mm, 72 kg).

Sizes common in UPS applications are easy to find in the table. DJ12-7 and DJ12-9 share the same 151 x 65 x 93 mm case (99 mm total height) and weigh 2.1 to 2.5 kg. DJ12-100 is listed in a 328 x 171 x 214 mm case (220 mm total height) with an F12 terminal. Five model names appear twice in the table: DJ6-12 with different dimensions, and DJ12-100, DJ12-120, DJ12-150 and DJ12-200 with the same dimensions and different weights (29 and 30 kg for DJ12-100, for example).

The page also explains in general terms what an SLA battery is and the strengths and weaknesses of lead-acid technology: it states that the price is one quarter to one sixth of other battery types, while weight and volume are large and charge and discharge requirements are strict. Constant-power discharge tables, internal resistance, charging voltage, design life, and the end voltage and temperature at which capacity is defined are not on the page; curves are presented as images.

Key points

  1. Series: DJ, sealed lead-acid (SLA/VRLA) with AGM technology; ABS container; CE.
  2. The table has 71 rows; capacities are at the 10-hour rate (C10).
  3. 6 V models: from DJ6-4 (4 Ah, 70 x 47 x 101 mm, 0.68 kg) to DJ6-300 (300 Ah, 295 x 178 x 345 mm, 46 kg).
  4. 12 V models: from DJ12-0.8 (0.8 Ah, 0.33 kg) to DJ12-260 (260 Ah, 520 x 269 x 220 mm, 72 kg).
  5. DJ12-7: 12 V, 7 Ah, 151 x 65 x 93 mm (99 mm total height), F1/F2 terminal, 2.1 kg.
  6. DJ12-100: 12 V, 100 Ah, 328 x 171 x 214 mm (220 mm total height), F12 terminal; 29 and 30 kg in two rows.
  7. DJ12-200: 12 V, 200 Ah, 522 x 238 x 218 mm (222 mm total height); 59 and 60 kg in two rows.
  8. Repeated model names: DJ6-12, DJ12-100, DJ12-120, DJ12-150 and DJ12-200.
  9. According to the page, a lead-acid battery costs 1/4 to 1/6 of other battery types.

Using it in design

  • Mark the capacity as C10 in the catalogue entry and allow for the difference when comparing with manufacturers' C20 tables.
  • Request the model's constant-power discharge table from the manufacturer for UPS runtime calculations; the page gives nominal capacity only.
  • For repeated model names (DJ12-100, DJ12-120, DJ12-150, DJ12-200, DJ6-12), confirm the weight and dimension variant with the manufacturer before ordering.
  • Use total height and terminal type (F1/F2, F3/F4, F11, F12) for battery cabinet layout, and select connection links to suit the terminal.
  • Use block weight for floor and rack loading: 29 to 30 kg for 100 Ah, 59 to 60 kg for 200 Ah.

Who should read it

Electrical designers selecting VRLA batteries for UPS and backup power systems, engineers laying out battery cabinets, and procurement teams.

Document contents

  1. Product introduction
  2. Features & Benefits
  3. Model List of DONGJIN sla rechargeable battery
  4. Curves of SLA rechargeable battery
  5. What is a Sealed Lead Acid (SLA) Battery?
  6. What are the advantages and disadvantages of lead-acid batteries?

Publication details

Authors
Dongjin Power
Publisher
Dongjin Power
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Dongjin Power Dongjin SLA Rechargeable Battery: model specification table. Dongjin Power. https://dongjin-battery.com/lead-acid-battery/ups-battery/sla-rechargeable-battery.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.