Technical guideFree to readYear not stated

HAMKO HPD Battery: model technical table

HAMKO

The HPD battery page of Bangladeshi manufacturer HAMKO gives the capacity, dimension and warranty table for eight 12 V flooded deep-cycle models, from HPD-60 to HPD-215, covering 60 Ah to 215 Ah.

On this page

Overview

The page presents HAMKO's HPD series in a single table. In the manufacturer's words the series rests on an improved design and enhanced flooded technology, with a thick-plate deep-cycle construction as the headline feature. All eight models in the table are 12 V blocks: HPD-60, HPD-80, HPD-100, HPD-130, HPD-165, HPD-180, HPD-200 and HPD-215. The number in the model name equals the rated capacity in ampere-hours.

Length, width and height are given in millimetres for each model. The smallest block, HPD-60, measures 304 x 171 x 225 mm, and the highest-capacity HPD-215 measures 410 x 270 x 209 mm. HPD-130, HPD-165 and HPD-180 share a 510 mm length, and HPD-165 and HPD-180 have identical dimensions (510 x 220 x 209 mm). The warranty is 12 months for HPD-60 and 18 months for the other seven models.

The feature list is qualitative: deep-cycle thick plates, low internal resistance, low temperature during charge and discharge, robust construction, high efficiency and low internal loss. The page does not state the discharge time or end voltage behind the capacity figure, block weight, a constant-power discharge table or design life. The table is therefore sufficient for layout and rack sizing, while autonomy calculations need discharge curves from the manufacturer. Flooded batteries require maintenance and ventilation.

Key points

  1. Eight models, all 12 V: HPD-60, 80, 100, 130, 165, 180, 200 and 215; capacity in Ah equals the model number.
  2. HPD-60: 304 x 171 x 225 mm, 12-month warranty.
  3. HPD-80: 344 x 174 x 255 mm; HPD-100: 410 x 175 x 240 mm.
  4. HPD-130: 510 x 180 x 209 mm; HPD-165 and HPD-180: 510 x 220 x 209 mm.
  5. HPD-200: 505 x 220 x 240 mm; HPD-215: 410 x 270 x 209 mm.
  6. The seven models from HPD-80 upward carry an 18-month warranty.
  7. The technology is flooded, with a thick-plate deep-cycle design.

Using it in design

  • Lay out battery racks and cabinets from the L x W x H values in the table; HPD-165 and HPD-180 share a footprint, so capacity can be raised without changing the rack.
  • Because the batteries are flooded, plan hydrogen ventilation, electrolyte spill containment and access for topping up in the battery room.
  • Before starting an autonomy calculation, obtain the constant-power table with its discharge time and end-voltage definition from the manufacturer; do not use the Ah figure alone in a kW calculation.
  • Take block weights from the manufacturer for floor loading; the page gives none.
  • Reflect the 12 and 18 month warranty periods in the battery replacement budget and the maintenance plan.

Who should read it

Designers selecting batteries for small UPS and inverter systems, and teams cataloguing battery products sold in South Asia.

Document contents

  1. Improved Design And Enhanced Flooded Technology
  2. Model table
  3. Characteristics of this Batteries

Publication details

Authors
HAMKO
Publisher
HAMKO
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

HAMKO HAMKO HPD Battery: model technical table. HAMKO. https://www.hamko.com.bd/show_product_details.php?product_name=hpd_battery

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.