Osaka NP VRLA Technical Data Sheet (Pakistan Accumulators)

Original title Osaka NP VRLA Technical Data Sheet: p.2

Pakistan Accumulators (Osaka)

Technical data sheet for Pakistan Accumulators' Osaka-branded NP series VRLA monobloc batteries: the model table carries a C10 label in the top header while the detailed capacity table uses the C20 rate.

On this page

Overview

The document is the technical data sheet for the NP series of VRLA (valve-regulated lead-acid) monobloc batteries that Pakistan Accumulators sells under the Osaka brand. The page contains the monobloc model table; the top header labels the C10 rate while the detailed table gives capacities at the C20 rate. Because the two labels point to different discharge rates for the same products, the rate used must be checked when capacity values are compared.

The data sheet serves as a reference for model-by-model capacity comparison of monobloc VRLA batteries used in small and medium UPS, alarm and backup power applications. The same capacity carries different values at C10 and C20 rates, so when sizing a battery string the detailed C20 table in the data sheet should be kept separate from the top C10 label.

Key points

  1. Series: Osaka NP VRLA monobloc batteries; publisher Pakistan Accumulators.
  2. The model table lists the monobloc batteries on one page.
  3. The top header uses a C10 label while the detailed capacity table uses the C20 rate.
  4. Capacity comparison requires stating the discharge rate (C10 or C20).

Using it in design

  • When comparing battery capacities, record whether each value belongs to the C10 or C20 rate.
  • In UPS battery string sizing, use the value that matches the rate in the manufacturer's detailed table.
  • Compare the model table capacities against other manufacturers' values at the same rate.

Who should read it

Electrical designers selecting VRLA batteries and teams cataloguing battery data.

Publication details

Authors
Pakistan Accumulators (Osaka)
Publisher
Pakistan Accumulators (Osaka)
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Pakistan Accumulators (Osaka) Osaka NP VRLA Technical Data Sheet: p.2. Pakistan Accumulators (Osaka). https://osaka.com.pk/wp-content/uploads/2021/01/Osaka-NP-VRLA-Technical-Data-Sheet.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.