Pilot Energy CBB specifications: Universal Long Life
Pilot Energy
Pilot Energy's CBB lead-carbon series Universal Long Life 12 V monoblocs: 28 to 130 Ah (C20), 4.0 to 7 mohm internal resistance, 1.7 times the charging performance of lead-acid and UL 1989 certification.
On this page
Overview
The page presents the Universal Long Life type from Taiwan-based Pilot Energy's CBB lead-carbon series. Stated uses are solar or wind energy storage, deep cycle systems, UPS emergency backup power and power systems. The manufacturer describes the batteries as maintenance-free, leak-free, high-temperature resistant, high-current, long-life and low self-discharge. They are said to combine features of lead-acid batteries and supercapacitors, start well at low temperature, and thanks to low internal resistance offer 1.7 times the charging performance of lead-acid batteries.
Safety and transport features include an effective explosion-proof venting design, compliance with IATA/A67 and IMDG/238 transport regulations, and UL 1989 certification. The model table gives six 12 V monoblocs: PL28-12-CBB (28 Ah), PL50-12-CBB (50 Ah), PL65-12-CBB (65 Ah), PL75-12I-CBB (75 Ah), PL100-12HLM-CBB (100 Ah) and PL130-12HLMA-CBB (130 Ah). Capacities are at the 20-hour discharge rate.
The table gives external dimensions, internal resistance, weight and maximum float charging current for each model. Internal resistance is 7 mohm for the 28 Ah model, 5.5 mohm for 50 Ah, 6 mohm for 65 Ah, 5.5 mohm for 75 Ah, 4.8 mohm for 100 Ah and 4 mohm for 130 Ah. Weight ranges from 8.3 kg to 37 kg and maximum float charging current from 8.4 A to 39 A. For dimensions, container height and height with terminals are shown separately on models of 75 Ah and above.
Key points
- Series: CBB lead-carbon, Universal Long Life; six 12 V models from 28 to 130 Ah (C20).
- Models: PL28, PL50, PL65, PL75, PL100 and PL130 (capacity 28, 50, 65, 75, 100, 130 Ah).
- Internal resistance: 7, 5.5, 6, 5.5, 4.8 and 4 mohm (respectively).
- Weight: 8.3, 14.1, 20.5, 23.3, 30 and 37 kg.
- Maximum float charging current: 8.4, 15, 19.5, 22.5, 30 and 39 A.
- Charging performance 1.7 times that of lead-acid batteries.
- UL 1989 certification; IATA/A67 and IMDG/238 transport compliance.
- Uses: solar and wind storage, deep cycle, UPS emergency backup, power systems.
Using it in design
- In UPS and hybrid backup applications, compare the lead-carbon battery with conventional VRLA for charge acceptance and low internal resistance.
- Check maximum float charging current (8.4 to 39 A) when selecting the charger and string protection fuse.
- Use the internal resistance values as input to short-circuit current and voltage drop calculations.
- Assess model weights (8.3 to 37 kg) against rack loading and manual handling rules.
Who should read it
UPS and energy-storage designers selecting lead-carbon batteries.
Publication details
- Authors
- Pilot Energy
- Publisher
- Pilot Energy
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Pilot Energy Pilot Energy CBB specifications: Universal Long Life. Pilot Energy. https://www.pilotbattery.com.tw/en/products-d.php?Key=1
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.