Technical guideFree to read2024

Rolls HL12-580WAGM High Load AGM Battery Datasheet (Rev.1, May 2024)

Original title Rolls HL12-580WAGM Rev.1 May 2024: p.1

Rolls Battery (Surrette)

A one-page manufacturer datasheet for a 12 V, 155 Ah (20-hour) VRLA AGM battery, giving dimensions, charging, capacity and constant-current discharge data.

On this page

Overview

The document introduces the HL12-580WAGM from the Rolls AGM-HL series. The series consists of VRLA AGM batteries designed for heavy-load discharge; the manufacturer claims 30% more power output than standard deep-cycle AGM models and a 15-year design life in float service such as high-power standby and UPS applications. The warranty is 3 years.

The physical section covers 12 V, 6 cells, the BCI specification, F12 (M8) terminals, ABS container and cover, and nylon strap handles. Weight is 47 kg and dimensions are 34.1 x 17.2 cm footprint with 28.5 cm height including terminals. The manufacturer notes that these values are calculated from sample data and vary with the manufacturing process.

Charge data are given at 25 degrees C: charge voltage 14.1-14.4 V, float voltage 13.5-13.6 V, recommended charge current 30 A and maximum charge current 45 A. Self-discharge is under 2% per month and internal resistance is 3.0 mOhm. Capacity is published separately at three rates: 155 Ah at the 20-hour rate (7.75 A), 145 Ah at the 10-hour rate (14.5 A) and 106 Ah at the 1-hour rate (106.3 A), which shows that a single Ah figure depends on discharge time.

The temperature table takes 25 degrees C as 100%, with 102% at 40 degrees C, 85% at 0 degrees C and 65% at minus 15 degrees C. The constant-current discharge table lists currents for 90, 60, 30, 20, 15, 10 and 8 minutes (from 76.69 A to 387.1 A) to a cut-off of 1.67 V per cell. The document covers a single battery model; string, rack or UPS compatibility needs a separate calculation.

Key points

  1. 12 V, 6 cells, 47 kg; dimensions 34.1 x 17.2 x 28.5 cm including terminals.
  2. Capacity: 155 Ah at 20 h (7.75 A), 145 Ah at 10 h (14.5 A), 106 Ah at 1 h (106.3 A).
  3. Charge voltage 14.1-14.4 V, float voltage 13.5-13.6 V at 25 degrees C; recommended charge current 30 A, maximum 45 A.
  4. Internal resistance 3.0 mOhm; self-discharge below 2% per month at 25 degrees C.
  5. Capacity versus temperature: 102% at 40 degrees C, 100% at 25, 85% at 0, 65% at minus 15.
  6. Constant current to 1.67 V per cell: 90 min 76.69 A, 60 min 106.3 A, 30 min 182.1 A, 15 min 299.1 A, 10 min 361.3 A, 8 min 387.1 A.
  7. Design life 15 years in float service, 3-year warranty, F12 (M8) terminals.

Using it in design

  • When sizing batteries, read capacity at the relevant rate: for runtimes of minutes, use the constant-current table for that duration instead of the Ah figure.
  • If the battery room is below 25 degrees C, apply the capacity loss from the table (85% at 0 degrees C) to the runtime.
  • Verify the charger or UPS rectifier float setting against 13.5-13.6 V per block and the maximum charge current against the 45 A limit.
  • Use the 47 kg block weight and the published dimensions for rack and floor-loading calculations, leaving margin because the sheet states dimensions vary with manufacturing.

Who should read it

Electrical designers sizing UPS battery systems and engineers cataloguing battery models.

Document contents

  1. Specifications
  2. Charge
  3. Capacity and temperature effect
  4. Constant current discharge table

Publication details

Authors
Rolls Battery (Surrette)
Publisher
Rolls Battery (Surrette)
Year
2024
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Rolls Battery (Surrette) (2024). Rolls HL12-580WAGM Rev.1 May 2024: p.1. Rolls Battery (Surrette). https://rollsbattery.com/wp-content/uploads/2024/05/HL12-580WAGM.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.