Accratech Linear/1 UPS model capacity table
Accratech
The UPS product page of US supplier Accratech lists the four models of the Linear/1 series (U91-1.5k, U91-3k, U91-5k, U91-8k) from 1.5 kW to 8 kW, with weight and typical full-load runtime (6 to 13 minutes) for each, efficiency of about 96% and noise of about 40 dB.
On this page
Overview
The page presents the Linear/1 uninterruptible power supply series for healthcare, industrial and IT facilities. The series has four models from 1.5 kW to 8 kW, with capacities published in kW. The U91-1.5k is a rackmount unit; the larger models are floor-standing and fitted with mobility wheels. Transfers during an outage are no-break. Internal batteries cover short outages, and external battery cabinets can be added for longer runtime. Output voltage can be configured from 100 V to 240 V.
The model table gives capacity, dimensions in inches, weight in pounds and typical runtime at full load. The U91-1.5k is 80 lb and 6 minutes, the U91-3k 280 lb and 13 minutes, the U91-5k 295 lb and 6.5 minutes, and the U91-8k 490 lb and 11 minutes. Runtimes are presented as typical values. The units include line conditioning: automatic voltage regulation, surge protection and transient noise filtering. Microprocessor-based control runs 18 built-in diagnostic routines, and an LCD display shows battery status, load and voltage.
The compliance list names UL 60601-1 and CAN/CSA C22.2 No. 601.1-M90 for medical safety, FCC Part 15 Class A and B and CISPR 22 for electromagnetic compatibility, and UL 1778 for general safety. The FAQ section states that most systems need a dedicated 200, 220, 230 or 240 V connection and cannot be plugged into a standard 120 V outlet. For maintenance it recommends an annual preventive inspection, battery testing and battery replacement every four years. The page also stresses that a UPS does not replace a generator and that the two are used together.
Key points
- Four models: U91-1.5k (1.5 kW), U91-3k (3 kW), U91-5k (5 kW), U91-8k (8 kW).
- Weights: 80 lb (about 36.3 kg), 280 lb (127.0 kg), 295 lb (133.8 kg) and 490 lb (222.3 kg).
- Typical full-load runtime: about 6 minutes at 1.5 kW, 13 minutes at 3 kW, 6.5 minutes at 5 kW, 11 minutes at 8 kW.
- Efficiency about 96%; operating noise about 40 dB.
- Output voltage selectable from 100 V to 240 V; most systems need a dedicated 200 to 240 V supply connection.
- Standards: UL 60601-1, CAN/CSA C22.2 No. 601.1-M90, UL 1778, FCC Part 15 Class A and B, CISPR 22.
- Recommended maintenance: annual preventive inspection and battery replacement every four years.
Using it in design
- Because capacities are published in kW, match the load on active power.
- Compare the typical 6 to 13 minute full-load runtimes with generator start time, and provide an external battery cabinet where longer runtime is needed.
- Plan the supply as a dedicated 200 to 240 V circuit; a standard 120 V outlet circuit is not sufficient.
- Use the unit weights in floor and rack loading calculations (490 lb for the 8 kW model).
- For small edge IT rooms or near-patient installations in North America, treat UL 60601-1 compliance as a selection criterion.
Who should read it
Engineers and facility managers selecting single-phase UPS units for small IT rooms, laboratories and healthcare facilities in North America.
Document contents
- UPS Products: model table
- Accratech UPS Systems
- Support and Maintenance
- UPS Battery Backup and Runtime Options
- Line Conditioning and Power Protection
- Technical Control and Diagnostics
- Flexible Configurations and Output Options
- Applications
- FAQs
Publication details
- Authors
- Accratech
- Publisher
- Accratech
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Accratech Accratech Linear/1 UPS model capacity table. Accratech. https://accratech.com/ups-products/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.