DKC TRIOTM6A0P official product page, ETIM characteristics

DKC

DKC's official product page describes the Trio TM series TRIOTM6A0P online UPS through its ETIM characteristics: single-phase, 6000 VA / 6000 W, output power factor 1, 88 mm high in a 19-inch rack, 12 kg, no internal battery and up to 4 units in parallel.

On this page

Overview

The page belongs to the Trio TM series in the medium-power UPS group (6 to 20 kVA) of the product catalogue of DKC (AO DKC), a manufacturer of cable management systems and low-voltage equipment. The product heading summarises the model as: online series, 6 kVA / 6 kW, single-phase input and output (1/1), EPO, USB, RS-232, terminal block, without battery. Characteristics are presented in a table organised by the ETIM classification (EC000382, UPS). The product code is TRIOTM6A0P.

Electrical values: output apparent power 6000 VA, output effective power 6000 W and output power factor 1. The UPS technology is online, the unit is single-phase and the input voltage range is 176 to 288 V. The output connection is by terminals, not sockets. Up to 4 units can run in parallel, a service bypass is provided, and cold start and auto-restart are supported. An external battery can be connected; the model has no internal battery.

Mechanical values: width 440 mm, height 88 mm, depth 580 mm and weight 12 kg. The construction type is a 482.6 mm (19-inch) device, and the 88 mm height corresponds to 2U. Interfaces are EPO, USB, RS-232, AS400 and SNMP, and a PC interface is provided. The warranty is 24 months. The page also gives the Russian classification of products by economic activity (OKPD 2: 26.20.40.111) and the foreign trade commodity code (8504403008).

The ETIM table does not include efficiency, input power factor, input current distortion, overload capability, output voltage regulation, charge current, battery string voltage or operating environment conditions. The "spare 6A" phrase in the heading is not explained as a characteristic row in the table. Input voltage is given as a range, not as a nominal value. For full design, the manufacturer's datasheet and user manual are taken from the certificates and download sections of the page.

Key points

  1. Model TRIOTM6A0P: Trio TM series online UPS, single-phase input and output (1/1).
  2. Output 6000 VA / 6000 W; output power factor 1.
  3. Input voltage range 176...288 V.
  4. Dimensions 440 x 88 x 580 mm (W x H x D); 19-inch rack type; weight 12 kg.
  5. No internal battery; an external battery is connected.
  6. Parallel operation up to 4 units; service bypass, cold start and auto-restart provided.
  7. Output connection by terminals; interfaces EPO, USB, RS-232, AS400, SNMP.
  8. Warranty 24 months; ETIM class EC000382.

Using it in design

  • With unity power factor, select the unit directly against the 6 kW load limit; where N+1 is required, work within the 4-unit parallel limit.
  • Because the model ships without batteries, size the external battery cabinet separately, taking string voltage and charge current from the manufacturer's datasheet.
  • Use 2U (88 mm) of height, 580 mm of depth and 12 kg in the rack plan, and reserve additional U space for external battery modules.
  • Since the output is on terminals, design a protected distribution (PDU or panel) at the UPS output.
  • Request the efficiency figure from the manufacturer for efficiency and heat-loss calculations; the ETIM table does not include it.
  • Connect the EPO input to the facility emergency shutdown circuit and the SNMP interface to the monitoring system.

Who should read it

Electrical designers and procurement engineers selecting 6 kVA class rack UPSs for edge sites and small server rooms.

Document contents

  1. Product Information
  2. Characteristics (ETIM EC000382, UPS)
  3. Accessories
  4. Certificates
  5. Download

Publication details

Authors
DKC
Publisher
DKC
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

DKC DKC TRIOTM6A0P official product page, ETIM characteristics. DKC. https://www.dkc.ru/en/catalog/811/triotm6a0p/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.