Technical guideFree to readYear not stated

Servo Star UPS Technical Specifications: Specification / kVA Row

Original title Servo Star UPS Technical Specifications, discrete Specification / KVA row

Servo Star India

Servo Star India UPS product page: single-phase 1-10 kVA and three-phase 10-100 kVA capacity groups, input 230 V ±15 percent / 415 V ±15 percent, ±1 percent output regulation, THD below 3 percent, galvanic isolation transformer at the output.

On this page

Overview

The document is the UPS product page of Servo Star in Ghaziabad, India. Servostar also makes voltage stabilizers, transformers and power distribution panels, and presents the UPS for instant power backup and for IT, medical and industrial use. The capacity row is given in two groups: 1, 2, 3, 4, 5, 8 and 10 kVA, and 10, 15, 20, 30, 40, 50, 60 and 100 kVA; 10 kVA appears in both groups.

The technical table gives an input voltage range of 230 V ±15 percent single phase and 415 V ±15 percent three phase (4 wire), and input frequency of 50 Hz ±6 percent. Output voltage is 230 V ±1 percent single phase and 220 V / 415 V three phase; voltage regulation is ±1 percent; output frequency is 50 Hz ±0.5 Hz; the waveform is true sinusoidal; THD is below 3 percent; crest factor is above 3:1. The inverter is IGBT-based digitally controlled PWM. The rectifier is an IGBT full-wave controlled rectifier with trickle, float and boost charging modes.

Battery voltage is 144 V DC for 1-5 kVA and 180 V DC for 3-10 kVA (custom options such as 192 V DC available); in three-phase systems the DC bus is 360 V DC (384 V DC optional). Overload is 110 percent for 10 minutes, 130 percent for 30 seconds and 130 percent for 5 seconds. The output has galvanic isolation (transformer), and short-circuit protection is by driver electronic sensing, with no fuse.

The page gives no power factor, efficiency, size or weight; the capacity entry is a descriptive row, not a specific order code. For data-centre use, capacity and power factor information should be obtained from the manufacturer.

Key points

  1. Capacity groups: 1, 2, 3, 4, 5, 8, 10 kVA (single phase) and 10, 15, 20, 30, 40, 50, 60, 100 kVA (three phase); 10 kVA appears in both.
  2. Input: 230 V ±15 percent (single phase), 415 V ±15 percent (3 phase 4 wire), 50 Hz ±6 percent.
  3. Output: 230 V ±1 percent (single phase), 220 V / 415 V (3 phase); regulation ±1 percent; 50 Hz ±0.5 Hz; THD below 3 percent.
  4. Crest factor above 3:1; continuous duty.
  5. Overload: 110 percent for 10 min, 130 percent for 30 s, 130 percent for 5 s.
  6. Battery voltage 144 V DC (1-5 kVA) and 180 V DC (3-10 kVA); custom 192 V DC possible.
  7. Three-phase DC bus 360 V DC, optional 384 V DC.
  8. Output galvanic isolation transformer; short-circuit protection by electronic sensing (no HRC/fuse).

Using it in design

  • The capacity row is a descriptor, not an order code; since 10 kVA is in both groups, state single- or three-phase output explicitly in the specification.
  • The page gives no power factor, so confirm kW with the manufacturer and check the load in kW.
  • Match the battery voltage (144, 180 or 192 V DC) to the battery string cell count.
  • Compare the overload curve (110 percent for 10 min, 130 percent for 30 s) with load inrush.
  • Account for fuseless electronic short-circuit protection in the selectivity calculation and protection coordination.

Who should read it

Electrical designers and procurement teams selecting small and medium UPS in the Indian market.

Document contents

  1. Product description
  2. UPS technical specifications: capacity, input, output, inverter, rectifier and charging, battery, overload, isolation, short circuit

Publication details

Authors
Servo Star India
Publisher
Servo Star India
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Servo Star India Servo Star UPS Technical Specifications, discrete Specification / KVA row. Servo Star India. https://www.servostarindia.com/ups-uninterruptible-power-supply/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.