Servokon Online UPS Brochure: Zenith 6-10 kVA Specifications (p.7)

Original title Servokon Online UPS brochure, Zenith 6-10kVA specifications p.7

Servokon

Servokon (India) online UPS brochure, Zenith 6 and 10 kVA single-phase models: 6 kVA/6 kW and 10 kVA/10 kW, 94 percent efficiency (up to 98 percent in ECO mode), 0 ms mains-to-battery transfer.

On this page

Overview

The document is the online UPS brochure, up to 800 kVA, of India's Servokon, founded in 1990. The company presents itself as a manufacturer of power conditioning equipment and transformers. The section examined covers the 6-10 kVA single-phase-in, single-phase-out Zenith series; the ZENITH-1106T20 (6 kVA / 6 kW) and ZENITH-1110T20 (10 kVA / 10 kW) models are in the table.

General features: high-frequency online double conversion, DSP control, active PFC with input power factor up to 0.99, 95 percent efficiency (up to 98 percent in ECO mode), a wide 110 to 290 Vac input range and 40 to 70 Hz frequency range, dual input for an independent bypass, 16 to 20 settable batteries, up to 12 A charging current, cold start and an optional built-in isolation transformer. Communication is through RS232, USB, RS485, SNMP and dry contacts.

Technical table: input voltage is 208/220/230/240 Vac; the input range is 110 to 176 Vac load-dependent and 176 to 290 Vac at full load; output voltage is settable from the LCD with ±1 percent regulation; THDv is below 1 percent on linear and 4 percent on non-linear load; crest factor is 3:1; overload is 10 minutes at 110 percent, 1 minute at 125 percent and 30 seconds at 125-150 percent. DC voltage is 192 Vdc (192 to 240 Vdc settable), standard charging is 5 A (default) and 12 A (optional); the standard model restores 90 percent of capacity in 8 hours. Efficiency is up to 94 percent at full load, at most 95 percent at 60 percent load and up to 98 percent in ECO mode. Transfer is 0 ms from mains to battery mode and typically 4 ms from inverter to bypass.

The document carries conflicting power factor information: the capacity row gives 6 kVA/6 kW and 10 kVA/10 kW and the heading states unity power factor, while the output power factor row in the table reads 0.9. The kW rating should therefore be confirmed with the manufacturer before it is taken as equal to kVA. Environment: 0 to 45 °C, altitude below 1500 m (1 percent derating per additional 100 m), IP 20; noise at 1 m is below 55 dB for 6 kVA and 58 dB for 10 kVA.

Key points

  1. ZENITH-1106T20: 6 kVA / 6 kW; ZENITH-1110T20: 10 kVA / 10 kW; single-phase input and output.
  2. Efficiency is at most 94 percent at full load, at most 95 percent at 60 percent load, up to 98 percent in ECO mode.
  3. Input range: 110 to 176 Vac load-dependent, 176 to 290 Vac at full load; frequency 40 to 70 Hz auto-sensing.
  4. Output voltage regulation ±1 percent; THDv below 1 percent linear and 4 percent non-linear; crest factor 3:1.
  5. Overload: 10 min at 110 percent, 1 min at 125 percent, 30 s at 125-150 percent.
  6. DC voltage 192 Vdc (192 to 240 Vdc settable), built-in 16 batteries (16 to 20 settable), charging 5 A (optional 12 A).
  7. Transfer from mains to battery mode is 0 ms; inverter to bypass is typically 4 ms.
  8. Dimensions 191 × 465 × 350 mm (6 kVA) and 191 × 495 × 350 mm (10 kVA); noise below 55 and 58 dB.
  9. Operation 0 to 45 °C, below 1500 m, IP 20.

Using it in design

  • Because the output power factor row says 0.9 while the heading says 1.0, confirm kW with the manufacturer and check capacity in kVA and kW separately.
  • Compare the load-dependent 110 to 176 Vac input range with measured supply data to see how it affects battery use on a weak supply.
  • Weigh the 98 percent ECO-mode efficiency against the 4 ms inverter-to-bypass transfer and load tolerance.
  • Match battery count (16 to 20) and DC voltage (192 to 240 Vdc) to the battery string; choose charging current by autonomy.
  • Apply the altitude and temperature derating values at the installation site.

Who should read it

Electrical designers and procurement teams selecting small and medium single-phase UPS.

Document contents

  1. Company overview
  2. Zenith series 6-10 kVA: features
  3. Zenith series 6-10 kVA: specifications
  4. Other UPS series and configurations

Publication details

Authors
Servokon
Publisher
Servokon
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Servokon Servokon Online UPS brochure, Zenith 6-10kVA specifications p.7. Servokon. https://servokon.co/pdfs/online-ups.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.