Hengli HR High Power: model specifications
Hengli Battery
The HR High Power series page from Jiangxi Hengli Technology Battery lists 22 lead-acid 12 V battery models for UPS and data-centre backup power, rated from 30 W to 900 W for a 15-minute discharge to an end voltage of 1.67 V per cell.
On this page
Overview
The page presents the HR High Power battery family of Jiangxi Hengli, a company founded in 1998 and headquartered in Fuzhou in China's Jiangxi province. The manufacturer states that a special grid design and alloy composition, high-quality separators, tight plate spacing and a compact structure lower internal resistance, raise energy density and limit temperature rise during high-power discharge. The series is recommended for large data centres, UPS and EPS power supplies and the backup power systems of power utilities.
The product parameter table lists 22 models: 21 CB models from CB12-30W to CB12-900W and the front-terminal FA12-400W. All are 12 V blocks. The rating is given not in ampere-hours but as watts for a 15-minute discharge to an end voltage of 1.67 V per cell (W/15 min), and it equals the number in the model name. The table does not state whether that watt figure is per cell or per block; for sizing, that definition should be obtained from the manufacturer in writing.
For each model the table gives length, width, container height and total height including terminals in millimetres, plus the terminal type (T2, M6, M8) and terminal position (A, B, C, D). The smallest model, CB12-30W, measures 151 x 65 x 94 mm (total height 100 mm) and the largest, CB12-900W, measures 520 x 268 x 220 mm (total 224 mm). The five models from CB12-680W to CB12-800W share one 522 x 240 x 219 mm container. Weight, Ah capacity, design life and discharge tables are not on the page.
Key points
- 22 models, all 12 V: 21 models from CB12-30W to CB12-900W and the front-terminal FA12-400W.
- Rating in W per 15 minutes to an end voltage of 1.67 V/cell; range 30-900 W.
- CB12-30W and CB12-32W: 151 x 65 x 94 mm, total height 100 mm, T2 terminal.
- CB12-110W to CB12-295W use M6 terminals; CB12-360W and above use M8.
- CB12-680W, 700W, 760W, 780W and 800W share one container: 522 x 240 x 219 mm, total height 223 mm.
- CB12-900W: 520 x 268 x 220 mm, total height 224 mm.
- FA12-400W is a slim front-terminal block: 507 x 109 x 223 mm, total height 226 mm.
- Highlighted features: strong current-carrying capacity at high discharge current, high active-material utilisation, low internal resistance.
Using it in design
- Size UPS batteries by the constant-power method; calculate string power only after the manufacturer confirms whether the W/15 min figure is per cell or per block.
- Compare the 1.67 V/cell end voltage with the UPS DC cut-off voltage; if they differ, request the discharge table for the relevant end voltage.
- Set battery-cabinet shelf spacing from the total height (terminals included) and choose cable lugs by terminal type (M6 or M8).
- Where front access is needed in 19-inch or 23-inch rack trays, consider the front-terminal FA12-400W.
- The five models sharing the 522 x 240 mm footprint allow a power step-up without changing the cabinet; obtain weights from the manufacturer for floor loading.
Who should read it
Electrical designers selecting high-rate UPS batteries and engineers laying out battery cabinets.
Document contents
- Product Features
- Main application areas and usage environment
- Product parameter table: HR High Power Battery Series
Publication details
- Authors
- Hengli Battery
- Publisher
- Hengli Battery
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Hengli Battery Hengli HR High Power: model specifications. Hengli Battery. https://baacebattery.com/en/lead-acid-battery/hr-high-power-series.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.