Technical guideFree to readYear not stated

LogicPower English product catalogue

LogicPower

LogicPower's 20-page catalogue brings together UPS and pure sine inverter models from 0.43 to 5 kVA, LiFePO4 and lead-acid batteries, hybrid solar inverters and home energy storage.

On this page

Overview

LogicPower introduces itself as a company active in electric power for over 17 years, with three service areas: batteries, UPS and solar power stations. The catalogue is divided accordingly: backup power systems, high-voltage and LiFePO4 batteries, solar systems (hybrid inverters and panels), UPS and inverter models, router UPS units, gel, AGM and other lead-acid batteries, and a CE conformity certificate. The document is a manufacturer's product selection catalogue; it has no runtime curves or detailed datasheets.

The UPS section falls into three groups. The pure sine UPS units (LP-UL2200VA 2200 VA/1600 W, LP-UL3500VA 3500 VA/2450 W, and the external-battery models from LPE-B-PSW-430VA+ 430 VA/300 W to LPE-W-PSW-5000VA+ 5000 VA/3500 W) are aimed at loads such as gas and solid-fuel boilers, circulation pumps and emergency lighting. The LPM-PSW inverters are listed from 700 W to 8000 W with 12, 24 or 48 V battery voltage, 6-10 ms switching time and 10-100 A charging current.

The smart-online group is double conversion: Smart-UPS 1000, 2000 and 3000 PRO (tower and RM versions; 1 kVA/900 W, 2 kVA/1800 W, 3 kVA/2700 W), with a 110-300 Vac input range and pure sine 230 V output at +/-1%. The manufacturer recommends them for servers, critical workstations and medical equipment; an SNMP card and external battery pack are optional. The catalogue covers 22 discrete UPS models in total.

On the battery side it lists LiFePO4 12.8 V (32-230 Ah), 25.6 V and 51.2 V products (the largest 51.2 V 230 Ah, 11776 Wh), a high-voltage home storage series of 15.36-40.96 kWh with 7000 cycles and a 10-year warranty, and gel (7-280 Ah), DZM, multi-gel and AGM lead-acid batteries with dimensions and weights. The last section is LogicPower Plus LLC's CE conformity certificate for LiFePO4 batteries: directives 2014/35/EU and 2014/30/EU and standards EN 62368-1 and EN IEC 61000-6-1/6-3.

Key points

  1. UPS models: LP-UL2200VA (2200 VA / 1600 W), LP-UL3500VA (3500 VA / 2450 W), and LPE-B-PSW-430VA+ (300 W) to LPE-W-PSW-5000VA+ (3500 W).
  2. LPM-PSW inverters 700-6000 W, 12/24/48 V battery, switching time 6-10 ms.
  3. Smart-UPS 1000/2000/3000 PRO (and RM): 1000/900, 2000/1800, 3000/2700 VA/W; input 110-300 Vac; output 230 V +/-1%.
  4. The catalogue covers 22 discrete UPS models.
  5. LiFePO4 batteries 12.8 V 32-230 Ah, 25.6 V and 51.2 V; largest 51.2 V 230 Ah 11776 Wh.
  6. High-voltage storage: 15.36-40.96 kWh, 7000 cycles, 10-year warranty, charging 0 to 45 C, discharging -10 to 50 C.
  7. Lead-acid batteries: gel 12 V 7-280 Ah, DZM 7-50 Ah, multi-gel (MG) 7-250 Ah, AGM 4-12 V.
  8. Router UPS units LP-418 PRO (18 W, 8000 mAh) and LP-430 PRO (30 W, 8800 mAh).
  9. Solar section: 4-11 kVA hybrid inverters; 450, 550 and 570 W half-cell panels.
  10. CE conformity certificate for LiFePO4 batteries: 2014/35/EU, 2014/30/EU.

Using it in design

  • Classify the catalogue UPS units for small office, boiler and network applications, not for data-centre critical load; the Smart-UPS PRO group is the only double-conversion option.
  • Read W and VA separately: for most models power factor is between 0.7 and 0.9 (for example 3500 VA / 2450 W).
  • Assess the 6-10 ms switching time of the LPM-PSW inverters against interruption-sensitive IT loads.
  • Tabulate battery V, Ah, size and weight from the catalogue; for LiFePO4, compare BMS current limits with the load current.
  • Calculate real runtime from your own load and battery capacity, not from the catalogue.

Who should read it

Designers and buyers selecting UPS, battery and solar components for small office, network and home backup power.

Document contents

  1. About the company
  2. Why LogicPower
  3. Backup power systems
  4. High-voltage home energy storage battery
  5. LiFePO4 batteries
  6. Solar energy systems: solar inverters and panels
  7. UPS (pure sine wave)
  8. Inverter (pure sine wave, LPM-PSW)
  9. UPS Smart-Online
  10. Router UPS and powerbank
  11. Gel, DZM, multi-gel and AGM batteries
  12. CE conformity certificate

Publication details

Authors
LogicPower
Publisher
LogicPower
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

LogicPower LogicPower English product catalogue. LogicPower. https://logicpower.eu/pdf/LogicPower_Catalog_English_compressed.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.