Faran online UPS catalogue, Titan Plus

Original title Faran online UPS catalogue, Titan Plus, PDF pp.1–2

Faran

A 12-page online UPS catalogue from Iranian brand Faran whose first two pages describe the Titan Plus high-frequency double-conversion single-phase series: 1 kVA / 900 W, 2 kVA / 1800 W, 3 kVA / 2700 W, 6 kVA / 5400 W and 10 kVA / 9000 W, with input power factor of at least 0.99 and AC-mode efficiency of at least 92% at 6-10 kVA.

On this page

Overview

The catalogue presents the online UPS products of the Faran brand with Persian introduction pages and English technical tables; the document is hosted on a distributor site. The first section is given to the Titan Plus series and later pages cover other series such as the rack-mount Vigor RT. Titan Plus is a double-conversion online UPS using high-frequency PWM. The introduction page lists the wide 110-300 V input range, active PFC, smart battery management, cold start from battery, EMI/RFI filters, ECO mode and an EPO input; RS-232 is standard and USB and SNMP are options.

The technical table gives five capacities, all at power factor 0.9. Rated voltage is set from the LCD at 208/220/230/240 VAC. The input voltage range is 110-300 VAC at half load and 160-300 VAC at full load; frequency is 40-70 Hz with auto sensing. Output voltage regulation is ±1%, frequency in battery mode is 50/60 Hz ±0.2 Hz and crest factor is 3:1. Voltage distortion is at most 2% on linear load and below 5% on non-linear load. Transfer from AC mode to battery mode takes 0 ms.

The table gives the two power groups in separate columns. In the 1-3 kVA group AC-mode efficiency is at least 90%, battery mode at least 87% and ECO mode at least 94%; transfer from inverter to bypass typically takes 4 ms, and the unit goes to bypass after 30 seconds at 105-150% overload and after 300 ms above 150%. In the 6-10 kVA group the efficiencies are at least 92%, 91% and 98%; transfer to bypass takes 0 ms, and the unit goes to bypass after 3 minutes at 105-125% and after 30 seconds at 125-150%.

Each capacity comes in two versions: S is the standard model with internal batteries and H is the long backup time model with external batteries. The DC bus is 36 V at 1 kVA, 96 V at 2 and 3 kVA and 240 V at 6 and 10 kVA; the standard models hold 3, 8, 8, 20 and 20 blocks of 9 Ah respectively. Charge current on the standard model is 1 A and recharge to 90% capacity takes 8 hours. Net weights run from 10.1 kg to 70.8 kg for the S version and 5.6 kg to 22.8 kg for H. Capacity is derated to 70% in frequency converter (CUCF) mode and to 90% when output is set to 208 VAC.

Key points

  1. Capacities: 1 kVA / 900 W, 2 kVA / 1800 W, 3 kVA / 2700 W, 6 kVA / 5400 W, 10 kVA / 9000 W; S standard (internal batteries) and H long backup versions.
  2. Input: 208/220/230/240 VAC, 110-300 VAC at half load, 160-300 VAC at full load, 40-70 Hz, power factor ≥ 0.99.
  3. Output: ±1% regulation, THD ≤ 2% on linear and < 5% on non-linear load, crest factor 3:1, AC to battery transfer 0 ms.
  4. Efficiency (1-3 kVA): AC ≥ 90%, battery ≥ 87%, ECO ≥ 94%; (6-10 kVA): AC ≥ 92%, battery ≥ 91%, ECO ≥ 98%.
  5. Overload (6-10 kVA): bypass after 3 minutes at 105-125% and after 30 seconds at 125-150%; (1-3 kVA): bypass after 30 seconds at 105-150% and after 300 ms above 150%.
  6. DC bus: 36 V (1 kVA), 96 V (2-3 kVA), 240 V (6-10 kVA); internal batteries 3, 8, 8, 20 and 20 blocks of 9 Ah.
  7. Charging: 1 A on the standard model; 8 hours to 90% capacity.
  8. Dimensions (WxDxH): 1 kVA 144 x 357 x 215 mm; 2-3 kVA 190 x 452 x 341 mm; 6-10 kVA 262 x 514 x 455 mm (H) and 262 x 514 x 735 mm (S).
  9. Net weight (S): 10.1, 20.5, 25.7, 64.1 and 70.8 kg; (H): 5.6, 11.0, 11.6, 22.1 and 22.8 kg.
  10. Derating: 70% in CUCF mode, 90% at 208 VAC output; ambient 0-40 °C, 20-90% humidity non-condensing.

Using it in design

  • Compare the load against the W value: at power factor 0.9 the 10 kVA model carries 9 kW, falling to 90% (8.1 kW) at 208 VAC output.
  • Prefer the 6-10 kVA group for critical IT load, where transfer to bypass is 0 ms; compare the typical 4 ms transfer of the 1-3 kVA group with load hold-up time.
  • With a 1 A charge current and 8-hour recharge on the standard model, record in the operations plan that autonomy drops on repeated outages; choose the H version with an external battery set for long autonomy.
  • Use the efficiency floors for the heat load: at 9 kW load and 92% efficiency the loss is about 0.78 kW.
  • Check floor and shelf loading with the S version weight; the 10 kVA standard model weighs 70.8 kg and stands 735 mm high.
  • Design the battery string for the 36, 96 or 240 V bus of the chosen capacity and select the external battery cabinet breaker accordingly.

Who should read it

Electrical designers selecting a 1-10 kVA single-phase online UPS, engineers planning edge and branch IT rooms and teams assessing suppliers in the Iranian market.

Document contents

  1. Titan Plus: Online High frequency UPS introduction (Persian)
  2. Technical Specifications: Capacity
  3. Input
  4. Output
  5. Efficiency
  6. Battery
  7. Alarm
  8. Environment
  9. Management
  10. Physical
  11. Vigor RT and other online series

Publication details

Authors
Faran
Publisher
Faran
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Faran Faran online UPS catalogue, Titan Plus, PDF pp.1–2. Faran. https://kianups.ir/wp-content/uploads/2022/06/Online-UPS_2.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.