Technical guideFree to readYear not stated

Meiji Electric official MUPS-600VA product page

Meiji Electric Philippines

Meiji Electric Philippines MUPS-600VA is a 600 VA (0.6 kVA) table-top UPS with a 12 V 7 Ah battery, 145-290 Vac input, PWM output waveform, 3-20 minute backup time and a weight of 4.9 kg.

On this page

Overview

The Meiji Electric Philippines product page presents the MUPS-600VA (Meiji Table Power Source). The unit is a small table-top UPS with 600 VA capacity. Output waveform is PWM/DC and output frequency 50 or 60 Hz. Input voltage is 145-290 Vac and output voltage is given as 195-255 Vac.

The internal battery is 12 V 7 Ah and backup time is listed as 3 to 20 minutes; the time depends on load and the page gives no specific load condition. Stated protections are high and low voltage, overload and short circuit, surge protection and intelligent battery management. A status LED display, automatic charging with the UPS off, ultra-fast transfer time and a silent function are listed.

Noise level is under 45 dB, operating temperature 0-45 C, relative humidity 10-90% non-condensing and weight 4.9 kg. The colour is black. The page is a single-model product summary; numeric transfer time, efficiency and case dimensions are not given.

Key points

  1. Model MUPS-600VA, 600 VA (0.6 kVA).
  2. Output waveform PWM/DC; output frequency 50 or 60 Hz.
  3. Input 145-290 Vac; output 195-255 Vac.
  4. Battery 12 V / 7 Ah.
  5. Backup time 3-20 minutes; no load condition stated.
  6. High/low voltage, overload, short-circuit and surge protection.
  7. Noise under 45 dB; operation 0-45 C; humidity 10-90% non-condensing.
  8. Weight 4.9 kg.

Using it in design

  • Do not take the 3-20 minute backup time as a guarantee without a stated load; do the battery calculation with the real load.
  • Check the wide output window (195-255 Vac) for voltage-sensitive loads.
  • Verify compatibility of the PWM output waveform with the target loads.
  • Do not use it where site temperature exceeds 45 C.
  • Ask the manufacturer separately for numeric transfer time and efficiency.

Who should read it

Buyers and IT staff on the Philippine market looking for a small table-top UPS.

Document contents

  1. Features
  2. Rated values
  3. Description

Publication details

Authors
Meiji Electric Philippines
Publisher
Meiji Electric Philippines
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Meiji Electric Philippines Meiji Electric official MUPS-600VA product page. Meiji Electric Philippines. https://meijielectric.ph/product/ups-mups-600va/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.