Myers MEPSM90-80 Series cut sheet (preliminary)
Original title Myers MEPSM90-80 Series cut sheet, PDF p.2; PRELIMINARY
Myers Critical Power Solutions
Cut sheet for Myers Critical Power Solutions' 208/120 V three-phase modular online UPS: 15 to 80 kVA, up to 4 power modules, 16 internal battery modules and up to 94 percent online efficiency.
On this page
Overview
The cut sheet presents the MEPSM90-80 series as a scalable, modular, double-conversion UPS. Capacity runs from 15 kVA/13.5 kW to 80 kVA/72 kW in seven steps, while the model selection table lists MEPSM9080-20k, 40k, 60k and 80k at 20 kVA/18 kW, 40 kVA/36 kW, 60 kVA/54 kW and 80 kVA/72 kW. The system is 208/120 V with auto-sensing 50/60 Hz. The document is stamped PRELIMINARY.
The enclosure takes up to four power modules: 80 kVA with 20 kVA modules or 60 kVA with 15 kVA modules. Power and battery modules are hot swappable, and a fully redundant power and battery module configuration is possible; if one module fails the remaining modules take over the load without interruption. The enclosure accepts 4, 8, 12 or 16 internal battery modules. The front carries a maintenance bypass switch, a 10-inch touchscreen and top cable entry, and single or dual utility input can be selected.
Electrical values are as follows: input range 121-253 V AC (line-to-line) depending on load and 40-70 Hz, output frequency 50/60 Hz ± 0.5 Hz, and full-load THD below 2 percent. Efficiency is up to 94 percent in online mode and 98 percent in ECO mode. Overload capacity is 105-110 percent for 60 minutes, 110-125 percent for 10 minutes, 126-150 percent for 1 minute and above 150 percent for 200 ms. The battery system is nominal ±120 V with programmable charge current of 8, 16, 24 or 32 A.
The sheet also tabulates internal battery runtimes: with 16 battery modules, 190 minutes at 5 kVA, 97 minutes at 10 kVA and 6 minutes at 80 kVA. Times vary with battery age and site conditions. Environmental limits are 0-40 °C and 5,200 ft above sea level; above 30 °C battery life is reduced and UPS capacity derates.
Key points
- Capacity steps: 15, 20, 30, 40, 45, 60 and 80 kVA (13.5 to 72 kW).
- The enclosure takes up to 4 x 20 kVA (80 kVA) or 4 x 15 kVA (60 kVA) power modules; 60 kVA N+1 is possible with 15 kVA modules.
- 4, 8, 12 or 16 internal battery modules; modules are hot swappable.
- Input 208/120 V, 121-253 V AC (line-to-line), 40-70 Hz; output 50/60 Hz ± 0.5 Hz; full-load THD below 2 percent.
- Efficiency up to 94 percent online and 98 percent in ECO mode.
- Overload: 105-110 percent for 60 min, 110-125 percent for 10 min, 126-150 percent for 1 min, above 150 percent for 200 ms.
- Programmable charge current of 8, 16, 24 and 32 A (by model); battery system ±120 V.
- Enclosure 23.6 x 43.3 x 79.1 in (W x D x H) and 657 lb; power module 74 lb, battery module 70 lb.
- With 16 battery modules, runtime is 190 min at 5 kVA, 42 min at 20 kVA, 18 min at 40 kVA and 6 min at 80 kVA.
- Noise below 69 dBA at 1 m; UL-1778, cUL, FCC A, RoHS and TAA approvals; 2-year warranty in the USA and Canada.
Using it in design
- Choose the number of enclosures and module layout against load growth and redundancy; 80 kVA with 20 kVA modules, or leave a spare module for N+1.
- Select the number of battery modules from the runtime table, and reduce the tabulated times for battery age and temperature.
- Check floor loading against enclosure and module weights (enclosure 657 lb, each module 70-74 lb).
- Account for derating and battery-life effects above 30 °C and above 5,200 ft in the cooling design.
- Use the overload curve and ECO-mode efficiency as inputs to energy-cost and upstream protection calculations.
Who should read it
Electrical designers and data-room operators who select modular UPS units for North American 208/120 V systems.
Document contents
- Product snapshot
- Features
- Model selection guide
- Internal battery runtimes
- Front view with and without door
Publication details
- Authors
- Myers Critical Power Solutions
- Publisher
- Myers Critical Power Solutions
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Myers Critical Power Solutions Myers MEPSM90-80 Series cut sheet, PDF p.2; PRELIMINARY. Myers Critical Power Solutions. https://www.myerscriticalpower.com/wp-content/uploads/2026/09/Myers-Critical-Power-Solutions_MEPS-M90-80-Series_Cut-Sheet.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.