Panther official product catalogue, Uninterruptible Power Supply block
Panther Philippines
The UPS section of Panther Philippines' 2022 product catalogue: PUP 501 (500 VA / 300 W), PUP 701 (700 VA / 420 W), PUP 1501 (1500 VA / 900 W) and PUP 3000 (3000 VA / 1800 W), 165-275 V AC input, 220 V AC output.
On this page
Overview
The catalogue brings Panther Philippines' transformers, automatic voltage regulators (AVR), voltage protectors, inverters and UPS units into one document. The UPS section describes a product group that supplies backup power to computers during power interruptions, with overload and short circuit protection. Four models are listed: PUP 501 (500 VA / 300 W), PUP 701 (700 VA / 420 W), PUP 1501 (1500 VA / 900 W) and PUP 3000 (3000 VA / 1800 W). Input voltage range is 165-275 V AC and output is 220 V AC. Power ratings correspond to 60 percent of the VA value.
For the UPS products, batteries are sold separately; the catalogue notes that 7 Ah 12 V and 9 Ah 12 V batteries are also available. Other sections of the catalogue list products that complement the UPS: voltage protectors with 160 to 250 V cut-off, 900 joule surge protection and a power-on delay of 15 seconds, 30 seconds or 3 minutes (PVP 2500 at 2500 W for general household equipment, PVP 3500 at 3750 W for air conditioners), protectors with 3 to 5 minute power-on delay, and AVR series.
The document is a product catalogue; the UPS section is limited to model, VA and W ratings, input and output voltage and battery option. Values such as efficiency, transfer time, runtime or waveform are not given in this section. The products are for small office and home computer loads, not for data centres.
Key points
- UPS models: PUP 501 (500 VA / 300 W), PUP 701 (700 VA / 420 W), PUP 1501 (1500 VA / 900 W), PUP 3000 (3000 VA / 1800 W).
- Input 165-275 V AC; output 220 V AC.
- Overload and short circuit protection are provided.
- 7 Ah 12 V and 9 Ah 12 V backup batteries are available separately.
- Voltage protector: cut-off range 160-250 V AC, 900 joule surge protection, 15 s / 30 s / 3 min power-on delay.
- Voltage protector models: PVP 2500 (2500 W, general household equipment) and PVP 3500 (3750 W, air conditioner).
- Catalogue code PC-22-07 (2022).
Using it in design
- Read the W rating as 60 percent of the VA value and verify the load list against the W figure.
- Because the input range is 165-275 V AC, assess whether an additional AVR is needed where mains fluctuation is high.
- Since runtime is not given in the catalogue, calculate it separately from battery capacity and load.
- For air-conditioner and motor loads, consider a voltage protector with power-on delay instead of a UPS.
Who should read it
Designers and suppliers selecting UPS and voltage-protection products for small office and computer loads.
Publication details
- Authors
- Panther Philippines
- Publisher
- Panther Philippines
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Panther Philippines Panther official product catalogue, Uninterruptible Power Supply block. Panther Philippines. https://panther.ph/wp-content/uploads/2022/08/Panther-Catalogue-20220714-v7.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.