Technical guideFree to readYear not stated

SATECH SPU Series True Galvanic Isolated On-line UPS Catalogue

Original title SATECH SPU True Galvanic Isolated Online UPS catalogue, PDF p.3

SATECH Power

SATECH Power SPU series galvanic isolated on-line UPS catalogue: 10 to 800 kVA standard (custom up to 2000 kVA), 0.8 output power factor, 93 to 95 percent efficiency for 10-160 kVA, 0 ms transfer.

On this page

Overview

The document is the catalogue for the SPU series true galvanic isolated on-line UPS from Taiwan-based SATECH Power. The series is offered as standard from 10 to 800 kVA, single or three-phase output, and can be customized up to 2000 kVA. Highlights are complete input-to-output galvanic isolation, a wide input range, serial and parallel redundant connection and an LCD and LED diagnostic panel. Applications listed include data centres, communications, oil and gas, hospitals, railroad signalling and military uses.

The technical table covers the 10, 15, 20, 30, 40, 50, 60, 80, 100, 120 and 160 kVA models (SPU 3310 to 33160). The input rectifier is phase-controlled SCR with a 15-second walk-in from 15 to 100 percent and about 99 percent efficiency; input voltage range is ±20 percent (wider on request) and frequency is 50 or 60 Hz ±7 Hz. For 80 kVA and above, a 12-pulse rectifier and input harmonic filter are listed to cut harmonic current. Batteries are maintenance-free lead-acid, 12 V × 29 pieces, and the UPS can start from battery without an AC source.

Inverter output is pure sine wave with voltage regulation of ±1 percent and output power factor of 0.8; phase shift is 120° ±0.5° at 100 percent unbalanced load and THD is below 3 percent on linear load. Overload is tolerated at 110 percent continuously, 110 to 124 percent for 15 minutes, 125 to 149 percent for 5 minutes and 150 percent or more for 30 seconds. Inverter efficiency at full load is 93 percent for 10 kVA and 95 percent for 160 kVA; overall efficiency is 91 to 93 percent. The static switch transfer between mains and inverter is 0 ms (zero-cross).

Physical values: two cabinet groups, 550 × 800 × 1600 mm and 1100 × 800 × 1600 mm; weight without batteries is 300 kg (10 kVA) to 1600 kg (160 kVA); noise at 1 m is below 65 to 67 dBA. EN 50091-1/-2 and CE are listed as standards, with UL 1778 as an option.

Key points

  1. SPU series is 10 to 800 kVA standard, up to 2000 kVA custom; single or three-phase output.
  2. Complete input-to-output galvanic isolation; wide input range of ±20 percent (wider on request).
  3. Input rectifier is phase-controlled SCR with about 99 percent efficiency; 12-pulse rectifier for 80 kVA and above.
  4. Output power factor 0.8; voltage regulation ±1 percent; THD below 3 percent on linear load.
  5. Overload: 110 percent continuous, 15 min at 110-124 percent, 5 min at 125-149 percent, 30 s at 150 percent and above.
  6. Inverter efficiency is 93 percent at 10 kVA and 95 percent at 160 kVA; overall efficiency 91 to 93 percent.
  7. Static switch transfer between mains and inverter is 0 ms, zero-cross.
  8. 10 kVA: 300 kg and 1.1 kW heat; 160 kVA: 1600 kg and 8.7 kW heat (without batteries).
  9. Operation at 0 to 40 °C and below 1500 m altitude; EN 50091-1/-2, CE; UL 1778 optional.

Using it in design

  • Calculate active power in kW: with an output power factor of 0.8, the 100 kVA model delivers 80 kW.
  • Reflect the effect of complete galvanic isolation on the earthing and neutral arrangement (TN-S / IT) in the single-line diagram.
  • Add the heat dissipation (1.1 kW at 10 kVA to 8.7 kW at 160 kVA) to the UPS room cooling load.
  • Account for floor loading using the weight without batteries (300 to 1600 kg) and add battery weight separately.
  • For 80 kVA and above, compare the 12-pulse rectifier and input harmonic filter options with the input THDi target.

Who should read it

Electrical designers and specification engineers seeking rugged galvanic isolated UPS with a wide input range.

Document contents

  1. Features and application areas
  2. SPU series features
  3. Technical specification: 10-160 kVA, 3-phase in / 3-phase out
  4. Technical specification: 200-800 kVA

Publication details

Authors
SATECH Power
Publisher
SATECH Power
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

SATECH Power SATECH SPU True Galvanic Isolated Online UPS catalogue, PDF p.3. SATECH Power. https://www.satechpower.com/archive/products/02-uninterruptible-power-system-UPS/True-Galvanic-Isolated-On-line-UPS/200-320KVA/Ctg-SPU-3P-UPS-2005.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.