Shindengen Discontinued Power-System Products and Service Information
Original title Shindengen discontinued power-system products and service information
Shindengen
Shindengen's discontinued power products page: repair and overhaul for the small UPAC/UPS series ended in December 2010, and the batteries are past their expected life, so replacement with another UPS is advised.
On this page
Overview
The document is the discontinued environment and energy products page in the support and service section of Japan's Shindengen Electric. It lists end-of-production dates for AC/DC power supplies, inverters, power-failure detection modules, DC/DC converters, AC adapters and EV/PHEV chargers, as well as the small UPS series UPAC and UPS. Because it is not a current product page, it is a historical reference rather than a source for current UPS models.
For the small UPS series the page states that acceptance of all repair and overhaul (OH), including battery replacement, ended in December 2010 for the UPAC and UPS series. The batteries used in this product group, including maintenance replacements, have passed their estimated life; because continued use of a spent battery can cause secondary failures such as leakage, odour, smoke or fire, users are asked to move to another company's UPS. The company states it does not handle a replacement unit.
End-of-production dates: 2003.12 for the UPAC-08, UPAC-11 and UPAC-15; 1998 for the UPAC-10S and 10E, the UPAC07E Model-7, 7A and 7B, and the UPS-500 series; 2002.09 for the UPAC07E Model-19; 2001.07 for the UPAC05 Model-3. In other categories, for example, the INV1000 inverter ended in 2009.09, the INV1000-II and INV1000SC in 2020.03, the INV125VA in 2025.09 and the SDQC-20 EV fast charger on 2018.10.26. The page thus documents that older Shindengen UPS units are out of service and that spares and service are no longer available.
The page gives no technical specification, capacity or model parameter; it contains only end-of-production, end-of-service and a battery-life warning.
Key points
- Repair and overhaul (OH) acceptance for the UPAC and UPS series ended in December 2010, including battery replacement.
- Batteries in these series, including maintenance replacements, are past their estimated life; leakage, smoke or fire risk is stated.
- The company offers no replacement model and asks users to move to another company's UPS.
- UPAC-08, UPAC-11 and UPAC-15 production ended 2003.12.
- UPAC-10S/10E, UPAC07E Model-7/7A/7B and the UPS-500 series ended in 1998.
- UPAC07E Model-19 ended 2002.09 and UPAC05 Model-3 2001.07.
- Inverters: INV1000 2009.09, INV1000-II and INV1000SC 2020.03, INV125VA 2025.09.
- Among EV fast chargers, the SDQC-20 was discontinued on 2018.10.26.
Using it in design
- If a Shindengen UPAC or UPS-500 series unit is on site, mark it in the inventory as a product without service or spare-part support.
- Treat the batteries of these units as past life; plan battery or unit replacement because of the leakage and fire risk.
- In a survey of current UPS data, treat this page as an end-of-production reference, not a model source.
- In a refurbishment of old installations, resize load power and autonomy against a new UPS.
- Since no replacement model is offered, do not wait for a manufacturer recommendation; select from current catalogue data.
Who should read it
Electrical engineers and facility managers building inventories and refurbishment plans for legacy installations.
Document contents
- Repair and overhaul information
- Discontinued power systems list: EV/PHEV chargers, AC/DC, inverters, DC/DC
- Small UPS: UPAC and UPS series
Publication details
- Authors
- Shindengen
- Publisher
- Shindengen
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Shindengen Shindengen discontinued power-system products and service information. Shindengen. https://www.shindengen.co.jp/support/abolition/eco_energy/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.