UPSAI Product Guide 2022: Pró Saver Senoidal UPS (No-break) Page

Original title UPSAI Guia de Produtos 2022, Pró Saver Senoidal page

UPSAI

The Pró Saver Senoidal page in UPSAI's 2022 product guide presents microprocessor-controlled UPS models of 1500, 1800, 2200 and 3200 VA with a sine waveform in both mains and battery mode and 15/30 minutes typical runtime.

On this page

Overview

UPSAI's Guia de Produtos 2022, published in Brazil, introduces a wide range of products by basic function, from autotransformers and isolator modules to stabilisers, audio and video conditioners and no-break (UPS) products. The page used here belongs to the Pró Saver Senoidal family and lists four models: Pró Saver 1500 VA, 1800 VA, 2200 VA and 3200 VA. The page lists product features rather than a detailed power table.

Pró Saver is recommended for applications where high-performance equipment needs power during an outage, such as servers, workstations, computers with PFC power supplies and advanced gaming systems. Microprocessor technology, a bivolt or monovolt voltage choice and a sine waveform in both mains and battery mode are the page's core features. The Flash series in the same guide, by contrast, gives an approximate sine wave in battery mode.

The unit includes regulated output, undervoltage and overvoltage protection, surge protection, a line filter and an overload sensor. Typical runtime is stated as 15 or 30 minutes for a home PC and 15-inch LCD monitor and can be extended with an external battery module (BA). The case is metal with a plastic front; visual and audible signalling, a plug-in cable, three-pin sockets and an external battery connector are provided. The page describes a computer and small-office class product, not a data-centre class one.

Key points

  1. Four models: Pró Saver 1500 VA, 1800 VA, 2200 VA and 3200 VA.
  2. Sine waveform in mains and battery mode (approximate sine in battery mode on the Flash series).
  3. Microprocessor technology; bivolt or monovolt voltage options.
  4. Regulated output, under/overvoltage protection, surge protection, line filter, overload sensor.
  5. Typical runtime 15/30 minutes (for a home PC and 15-inch LCD monitor); extendable with an external battery module (BA).
  6. Target loads: servers, workstations, computers with PFC power supplies, advanced gaming systems.
  7. Metal case with plastic front; visual and audible signalling; three-pin sockets; external battery connector.

Using it in design

  • Because a sine output suits PFC power supplies, prefer it over stepped-sine models for such loads.
  • The 15/30 minute figure is for a home PC; scale runtime for the real load and calculate the external battery module (BA) need.
  • Choose the bivolt or monovolt version at order stage against site voltage.
  • These products are for small loads; use a double-conversion UPS for critical white-space load.
  • Ask the manufacturer for the current technical table for power and model details.

Who should read it

Those selecting UPSs for small loads and computer systems on the Brazilian market, and catalogue maintainers.

Document contents

  1. Basic function of the products
  2. No-break Flash Interactive
  3. No-break Pró Saver Senoidal
  4. Audio and video conditioners
  5. Other products

Publication details

Authors
UPSAI
Publisher
UPSAI
Year
Year not stated
Document language
French
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

UPSAI UPSAI Guia de Produtos 2022, Pró Saver Senoidal page. UPSAI. https://www.upsai.com.br/pdf/upsai-catalogo-2022.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.