TS EN 50600-2-4: Telecommunications cabling infrastructure
Türk Standardları Enstitüsü (TSE)
TS EN 50600-2-4 is part of the EN 50600 series and covers the telecommunications cabling infrastructure of the data centre; it is the Turkish adoption of EN 50600-2-4:2023.
This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
TS EN 50600-2-4 covers the data centre's telecommunications cabling infrastructure. The EN 50600-1 availability classes also apply to cabling on its own, so the cabling path can be given a class independent of power and cooling.
The example in the series overview shows this separation: a site can be Class 3 for power and Class 2 for cabling. Details such as cable types, distances or path separation are set out in the text of the part.
According to the TSE catalogue, TS EN 50600-2-4 was accepted on 24 April 2023 and is in force. The document is a Turkish-language text of 65 pages and is based on EN 50600-2-4:2023. The catalogue lists it as replacing TS EN 50600-2-4:2015. The TSE catalogue record is the reference; when citing TS EN 50600-2-4 in Turkey, state the EN 50600-2-4:2023 edition alongside it.
Key points
- Scope: telecommunications cabling infrastructure.
- The class is assigned to cabling on its own; Class 3 for power with Class 2 for cabling is possible.
- TSE catalogue: accepted 24 April 2023, status in force.
- Document language: Turkish; 65 pages; based on EN 50600-2-4:2023.
- Replaces: TS EN 50600-2-4:2015.
Using it in design
- In Turkish project specifications, write the TS EN 50600-2-4 designation together with the EN 50600-2-4:2023 edition it is based on.
- The document is published as a Turkish text, so Turkish terms in specifications can follow it.
- Keep the cabling class selector separate, and document the reason whenever it is chosen lower than the power class.
- Take pathway and separation rules from the text of the part.
Who should read it
For designers of data centre structured cabling and network infrastructure.
Related standards
- EN 50600-2-4
- EN 50600-2-4:2023
Publication details
- Authors
- Türk Standardları Enstitüsü (TSE)
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- 2023
- Document number
- TS EN 50600-2-4
- Document language
- Turkish
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
TSE standard texts are sold by TSE; this record holds catalogue metadata and the official link only.
Citation
Türk Standardları Enstitüsü (TSE) (2023). TS EN 50600-2-4: Telecommunications cabling infrastructure. Türk Standardları Enstitüsü (TSE). TS EN 50600-2-4. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084108055083078053048085104122080051071104050112116116083055070050080082105047048082081116048073116074107079115083066114054117105068097109098122069057116082043069077057101086105054122114043105075071086114120050107115050051050050072057108113043055075121083080109078076085068098074109090109122087079049114065073099099097071116081056067047073115102050067076101047074121072080082079080066111103061061
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.