TS EN 60076-10: Determination of transformer sound levels
Original title TS EN 60076-10: Güç transformatörleri - Bölüm 10: Ses seviyelerinin belirlenmesi
Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü
TS EN 60076-10 is a 131-page standard adopted in the TSE catalogue on 9 January 2017 and currently in force; it covers determination of transformer sound levels and is based on EN 60076-10:2016.
This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
TS EN 60076-10 is a standard defining methods for determining transformer sound levels. The standard covers methods of measuring transformer noise; its 131 pages reflect the level of detail in the measurement methods.
According to the TSE catalogue the standard was adopted on 9 January 2017, carries status U (standard in force) and has English as its text language; it runs to 131 pages. The source edition is given as EN 60076-10:2016.
The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.
Key points
- Adopted 9 January 2017, status U (standard in force).
- Text language English, 131 pages.
- Source edition: EN 60076-10:2016.
- Subject: a standard defining methods for determining transformer sound levels.
Using it in design
- Limit transformer sound level in the specification and state that measurement follows this standard.
- Assess transformer placement and acoustic barriers against neighbouring buildings and environmental noise limits.
- Include sound measurement in factory acceptance tests.
Who should read it
Engineers handling site noise and transformer specifications.
Related standards
- EN 60076-10:2016
Publication details
- Authors
- Türk Standardları Enstitüsü
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- 2017
- Document number
- TS EN 60076-10
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.
Citation
Türk Standardları Enstitüsü (2017). TS EN 60076-10: Güç transformatörleri - Bölüm 10: Ses seviyelerinin belirlenmesi. Türk Standardları Enstitüsü (TSE). TS EN 60076-10. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084118047104110078113107086083098117090055050073069047098102089097100071087111074049073057057105077056054070105057090083104101118056074078051084080048073087089065068107056100069090053105099122054052052116106072099081043119069072100085104090105088116068115098098105074081048105080068051054098081101102069090054102074117067110108088118085056097104119105073071051087079043078097098069116108065061061
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.