TS EN 60076-3: Insulation levels and dielectric tests
Original title TS EN 60076-3: Güç transformatörleri - Bölüm 3: Yalıtım seviyeleri, dielektrik deneyleri ve havadaki harici yalıtma aralıkları (IEC 60076-3:2013)
Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü
TS EN 60076-3 is a 61-page standard adopted in the TSE catalogue on 13 February 2014 and currently in force; it covers insulation levels and dielectric tests and is based on EN 60076-3:2013.
This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
TS EN 60076-3 is a standard defining insulation levels, dielectric tests and external clearances in air. The standard is the Turkish adoption of the IEC 60076-3:2013 text and deals with voltage withstand and clearances in air.
According to the TSE catalogue the standard was adopted on 13 February 2014, carries status U (standard in force) and has Turkish as its text language; it runs to 61 pages. The source edition is given as EN 60076-3:2013. The catalogue lists amending documents: TS EN 60076-3/A1:2018.
The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.
Key points
- Adopted 13 February 2014, status U (standard in force).
- Text language Turkish, 61 pages.
- Source edition: EN 60076-3:2013.
- Subject: a standard defining insulation levels, dielectric tests and external clearances in air.
- Amending documents: TS EN 60076-3/A1:2018.
Using it in design
- Check air clearances between transformer terminals and busbars according to this standard.
- Select lightning impulse withstand level together with network and SPD coordination.
- Define dielectric test scope in factory acceptance tests.
Who should read it
Medium-voltage transformer and switchgear designers.
Related standards
- EN 60076-3:2013
Publication details
- Authors
- Türk Standardları Enstitüsü
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- 2014
- Document number
- TS EN 60076-3
- Document language
- Turkish
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre tr; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.
Citation
Türk Standardları Enstitüsü (2014). TS EN 60076-3: Güç transformatörleri - Bölüm 3: Yalıtım seviyeleri, dielektrik deneyleri ve havadaki harici yalıtma aralıkları (IEC 60076-3:2013). Türk Standardları Enstitüsü (TSE). TS EN 60076-3. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084107105117056067077080084075055054075078049048070072088082115101043054070087065079100069102111106065101049097055120079082079047116103105089072117073106051098122075075102116115119109105090054055055109089069079082103117065099115048056115101043084117083074109116084106112098104119075101083120070098065080097052069097043084090085099099055122098074072083048117073101116103077113090115098069065061061
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.