TS EN IEC 60076-11: Dry-type transformers

Original title TS EN IEC 60076-11: Güç transformatörleri - Bölüm 11: Kuru tip transformatörler

Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü

TS EN IEC 60076-11 is a 69-page standard adopted in the TSE catalogue on 19 November 2018 and currently in force; it covers dry-type transformers and is based on EN IEC 60076-11:2018.

This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

TS EN IEC 60076-11 is a standard covering dry-type power transformers. The standard defines requirements and tests for dry-type transformers, which use solid insulation and air cooling instead of oil.

According to the TSE catalogue the standard was adopted on 19 November 2018, carries status U (standard in force) and has English as its text language; it runs to 69 pages. The source edition is given as EN IEC 60076-11:2018. The catalogue lists amending documents: TS EN IEC 60076-11/AC:2019.

The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.

Key points

  1. Adopted 19 November 2018, status U (standard in force).
  2. Text language English, 69 pages.
  3. Source edition: EN IEC 60076-11:2018.
  4. Subject: a standard covering dry-type power transformers.
  5. Amending documents: TS EN IEC 60076-11/AC:2019.

Using it in design

  • Consider dry-type units for indoor transformer rooms because of fire load and oil containment requirements.
  • State the thermal class and ambient conditions in the specification.
  • Add dry-type losses to the transformer room ventilation calculation.

Who should read it

Electrical designers selecting indoor transformers.

Related standards

  • EN IEC 60076-11:2018

Publication details

Authors
Türk Standardları Enstitüsü
Publisher
Türk Standardları Enstitüsü (TSE)
Year
2018
Document number
TS EN IEC 60076-11
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.

Citation

Türk Standardları Enstitüsü (2018). TS EN IEC 60076-11: Güç transformatörleri - Bölüm 11: Kuru tip transformatörler. Türk Standardları Enstitüsü (TSE). TS EN IEC 60076-11. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084118082057120078090098107111074082076043048115073097052103090056097051117106053112114111107066098049080085104104084049120088090114050111073065083122113057071104080048090055100066117087050070098048050043054102086070078085047082080052051103076090103098089108112057115052100075075101051047112050090079082078074076100078078043114105076057054090102098047071119100097079111057073089089057082065061061

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.