TS EN IEC 60076-22-3: Transformer liquid-to-air heat exchangers
Original title TS EN IEC 60076-22-3: Güç transformatörleri- Bölüm 22-3: Güç transformatörü ve reaktör ek parçaları- Havalı ısı eşanjörlerinde kullanılan yalıtkan sıvı
Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü
TS EN IEC 60076-22-3 is a 30-page standard adopted in the TSE catalogue on 30 September 2019 and currently in force; it covers transformer liquid-to-air heat exchangers and is based on EN IEC 60076-22-3:2019.
This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
TS EN IEC 60076-22-3 is a standard on insulating liquid in liquid-to-air heat exchangers of transformers. The standard defines requirements for heat exchangers that transfer heat from the insulating liquid to air.
According to the TSE catalogue the standard was adopted on 30 September 2019, carries status U (standard in force) and has English as its text language; it runs to 30 pages. The source edition is given as EN IEC 60076-22-3:2019.
The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.
Key points
- Adopted 30 September 2019, status U (standard in force).
- Text language English, 30 pages.
- Source edition: EN IEC 60076-22-3:2019.
- Subject: a standard on insulating liquid in liquid-to-air heat exchangers of transformers.
Using it in design
- Provide airflow clearances for the air-cooled exchanger in outdoor transformer layouts.
- Include fan and cooling auxiliary circuits in the auxiliary load and redundancy calculation.
- State the heat exchanger type explicitly in the specification.
Who should read it
Electrical engineers selecting transformer cooling arrangements.
Related standards
- EN IEC 60076-22-3:2019
Publication details
- Authors
- Türk Standardları Enstitüsü
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- 2019
- Document number
- TS EN IEC 60076-22-3
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.
Citation
Türk Standardları Enstitüsü (2019). TS EN IEC 60076-22-3: Güç transformatörleri- Bölüm 22-3: Güç transformatörü ve reaktör ek parçaları- Havalı ısı eşanjörlerinde kullanılan yalıtkan sıvı. Türk Standardları Enstitüsü (TSE). TS EN IEC 60076-22-3. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084109043065052120074118089097088051112066070050116072086111084081070043073116121052100065081047053108054090106113120078067088121118066098077116112068104102115113118071102086081081073104100110057090117049052115104053080068056087116085108076056055051090076052078056119069103111057073065120109076097121047054118043074055078088068104110068104101111053068122076119071111114050081121101098077103061061
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
