TS HD 60364-5-557: Auxiliary circuits
Original title TS HD 60364-5-557: Binalarda elektrik tesisatı - Bölüm 5-559: Elektrik donanımının seçimi ve kurulması - Yardımcı devreler
Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü
TS HD 60364-5-557 is a 33-page standard adopted in the TSE catalogue on 13 February 2014 and currently in force; it covers auxiliary circuits and is based on HD 60364-5-557:2013.
This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
TS HD 60364-5-557 is a standard on selection and erection of auxiliary circuits in electrical installations. The standard gives rules for the erection of auxiliary circuits such as control and signalling.
According to the TSE catalogue the standard was adopted on 13 February 2014, carries status U (standard in force) and has English as its text language; it runs to 33 pages. The source edition is given as HD 60364-5-557:2013. The catalogue lists amending documents: TS HD 60364-5-557/A11:2016.
The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.
Key points
- Adopted 13 February 2014, status U (standard in force).
- Text language English, 33 pages.
- Source edition: HD 60364-5-557:2013.
- Subject: a standard on selection and erection of auxiliary circuits in electrical installations.
- Amending documents: TS HD 60364-5-557/A11:2016.
Using it in design
- Plan cabling of switchgear and UPS control circuits on routes separate from power cables.
- Determine the need for an independent DC or UPS source for auxiliary supply.
- Add control circuit protection and isolation arrangements to the single-line diagram.
Who should read it
Switchgear and control circuit designers.
Related standards
- HD 60364-5-557:2013
Publication details
- Authors
- Türk Standardları Enstitüsü
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- 2014
- Document number
- TS HD 60364-5-557
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz. Katalog Türkçe başlığı yanlışlıkla Bölüm 5-559 yazar; TS No ve İngilizce başlık 5-557 der. Özgün başlık korunmuştur.
Citation
Türk Standardları Enstitüsü (2014). TS HD 60364-5-557: Binalarda elektrik tesisatı - Bölüm 5-559: Elektrik donanımının seçimi ve kurulması - Yardımcı devreler. Türk Standardları Enstitüsü (TSE). TS HD 60364-5-557. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084108055083078053048085104122080051071104050112116116083055070050080082105047048082081116048073116067082105109066052047089088098112070075050052104114047103103098077118074047084111079109121047100097065105086119066047089119069069101068065114085112072084053066115078080113075121076117109108057069116068088078121043082068111114122090054112097043113072055053052083047050104090088097055050098119061061
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.