TS HD 60364-7-722: Electric vehicle supply installations

Original title TS HD 60364-7-722: Alçak gerilim elektrik tesisleri - Özel tesisler ve yerler için kurallar - Elektrikli taşıtların besleme kaynağı

Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü

TS HD 60364-7-722 is a 39-page standard adopted in the TSE catalogue on 28 January 2019 and currently in force; it covers electric vehicle supply installations and is based on HD 60364-7-722:2018.

This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

TS HD 60364-7-722 is a standard with particular installation rules for the supply of electric vehicles. The standard defines particular rules for electric vehicle charging points in low-voltage installations.

According to the TSE catalogue the standard was adopted on 28 January 2019, carries status U (standard in force) and has English as its text language; it runs to 39 pages. The source edition is given as HD 60364-7-722:2018.

The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.

Key points

  1. Adopted 28 January 2019, status U (standard in force).
  2. Text language English, 39 pages.
  3. Source edition: HD 60364-7-722:2018.
  4. Subject: a standard with particular installation rules for the supply of electric vehicles.

Using it in design

  • Include charging points in the data centre car park in the main distribution calculation and demand factor.
  • Check protection and residual-current requirements of charging circuits against this part.
  • Prefer feeding charging loads separately from the critical load busbar.

Who should read it

Facility electrical designers and site engineers.

Related standards

  • HD 60364-7-722:2018

Publication details

Authors
Türk Standardları Enstitüsü
Publisher
Türk Standardları Enstitüsü (TSE)
Year
2019
Document number
TS HD 60364-7-722
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.

Citation

Türk Standardları Enstitüsü (2019). TS HD 60364-7-722: Alçak gerilim elektrik tesisleri - Özel tesisler ve yerler için kurallar - Elektrikli taşıtların besleme kaynağı. Türk Standardları Enstitüsü (TSE). TS HD 60364-7-722. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084115121051088078116069068071104074065079050104112056070103071089077087082111081071088114057115057104090048056083119085056107069055116051113111090121075121051069048117086072084118051090080115089078050049074084111099054075113115074073065072109121111081103104066103054071112053057098102115108082117050105109056107109087054085100081071054048116110114080086115068069081055101119089097122118103061061

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.