TS IEC 60076-8: Transformer application guide

Original title TS IEC 60076-8: Güç transformatörleri - Bölüm 8: Uygulama kılavuzu

Türk Standardları Enstitüsü (TSE) · Türk Standardları Enstitüsü

TS IEC 60076-8 is a 90-page standard adopted in the TSE catalogue on 18 February 2016 and currently in force; it covers transformer application guide and is based on IEC 60076-8:1997.

This document is sold by Türk Standardları Enstitüsü (TSE) and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

TS IEC 60076-8 is an application guide for power transformers. The guide describes transformer behaviour and its effect on circuits and networks from an application viewpoint. The source edition dates from 1997.

According to the TSE catalogue the standard was adopted on 18 February 2016, carries status U (standard in force) and has English as its text language; it runs to 90 pages. The source edition is given as IEC 60076-8:1997.

The Turkish standard is the national adoption of the corresponding international or European text; as a commercial publication, its full text is obtained through TSE. When citing it in a design file, writing the adoption date, source edition and any amendments together makes the edition relied on traceable.

Key points

  1. Adopted 18 February 2016, status U (standard in force).
  2. Text language English, 90 pages.
  3. Source edition: IEC 60076-8:1997.
  4. Subject: an application guide for power transformers.

Using it in design

  • Assess transformer impedance and vector group selection together with the short-circuit current calculation.
  • Reflect inrush current and parallel operation conditions in protection settings.
  • Because of the older edition date, compare results with current parts of the 60076 series.

Who should read it

Engineers selecting transformers and coordinating protection.

Related standards

  • IEC 60076-8:1997

Publication details

Authors
Türk Standardları Enstitüsü
Publisher
Türk Standardları Enstitüsü (TSE)
Year
2016
Document number
TS IEC 60076-8
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Yalnızca herkese açık TSE katalog metadatası okundu; ücretli standart metni açılmadı, indirilmedi veya özetlenmedi. Belge dili TSE katalog kaydına göre en; Türkçe künye ve özet çevirileri belge dilinden ayrıdır. Kabul tarihi yayım/tercüme tarihiyle bir tutulmaz.

Citation

Türk Standardları Enstitüsü (2016). TS IEC 60076-8: Güç transformatörleri - Bölüm 8: Uygulama kılavuzu. Türk Standardları Enstitüsü (TSE). TS IEC 60076-8. https://intweb.tse.org.tr/Standard/Standard/Standard.aspx?081118051115108051104119110104055048065082077055103076076056084112049120072103120100087043122054077113051086069108106122069089066108097100075114102108047102078047071068057108071106105056078112090107083047114081088048057090083066114119117085067111103051117102050099099052099067105112114107101073084118081112102076055067105083049119119055080080078057079111099121076057099050073121073057065114066079080104120052110086082072077102109089111068047110112065061061

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.