StandardCitation2021

Information technology - Data centre facilities and infrastructures - Part 4: Environmental control

ISO/IEC · ISO/IEC JTC 1

The counterpart of EN 50600-2-3, this standard addresses temperature, fluid movement, humidity, particulate and vibration control in data centres according to availability, security and energy-efficiency-enablement classes.

On this page

Overview

ISO/IEC 22237-4 is the standard that defines environmental control in data centres and is the international counterpart of EN 50600-2-3. Its scope goes beyond temperature: it covers temperature control, fluid movement control and relative humidity control, as well as particulate control and vibration. This breadth indicates that cooling is not only a capacity calculation; the whole environment in which the equipment operates is a design subject.

The standard rests on the availability, security and energy-efficiency-enablement classification of ISO/IEC 22237-1. The requirements for environmental control systems therefore depend on the class chosen for the facility. The physical security of the environmental control systems is also within scope; unauthorised access to cooling infrastructure could disturb environmental conditions and threaten service continuity.

The document is Edition 1, published on 29 October 2021. It runs to 24 pages and replaces ISO/IEC TS 22237-4:2018. The record rests only on the IEC webstore abstract and product detail; because the full text is not openly available, class-specific numeric requirements are not given on this page.

The limit is that the public abstract can list the scope but does not reveal the detailed requirements. In design work the standard should be read together with the ASHRAE TC9.9 Thermal Guidelines and compared with EN 50600-2-3. Once the facility's target class is set, cooling plant and distribution redundancy should be verified against that class.

Key points

  1. Covers temperature control, fluid movement control and relative humidity control.
  2. Covers particulate control and vibration.
  3. Covers the physical security of environmental control systems.
  4. Based on the availability, security and energy-efficiency-enablement classification of ISO/IEC 22237-1.
  5. Edition 1 was published on 29 October 2021, runs to 24 pages and replaces ISO/IEC TS 22237-4:2018.
  6. It is the counterpart of EN 50600-2-3.

Using it in design

  • In the cooling module, apply class-based redundancy rules (N, N+1, 2N) to cooling plant and distribution.
  • Add humidity, filtration and vibration fields to the cooling-equipment catalogue so the design check covers the full environmental scope, not just temperature.
  • Include the physical security of environmental control systems in the facility security design.
  • Set the target facility class at project start and verify cooling redundancy against it.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Check cooling capacity alongside your design

Review zone heat loads, available capacity and the capacity balance after the largest unit is lost in SoSo CAD.

Request a demo
Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Who should read it

Engineers designing data centre cooling and environmental control, and consultants checking class-based compliance.

Related standards

  • EN 50600-2-3
  • ASHRAE TC9.9 Thermal Guidelines
  • ISO/IEC 22237-1

Publication details

Authors
ISO/IEC JTC 1
Publisher
ISO/IEC
Year
2021
Document number
ISO/IEC 22237-4:2021
Document language
English
Source type
Standard
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

ISO/IEC JTC 1 (2021). Information technology - Data centre facilities and infrastructures - Part 4: Environmental control. ISO/IEC. ISO/IEC 22237-4:2021. https://webstore.iec.ch/en/publication/71830

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.