NFPA 855, Standard for the Installation of Stationary Energy Storage Systems
NFPA · National Fire Protection Association
NFPA 855 sets minimum installation requirements to mitigate hazards of stationary energy storage systems (ESS), increasingly relevant for lithium-ion UPS batteries and on-site BESS.
On this page
Overview
NFPA 855 is the standard of the US National Fire Protection Association (NFPA) for the installation of stationary energy storage systems. Its purpose is to provide minimum requirements for mitigating hazards associated with energy storage systems (ESS). The current edition is 2026 and the next edition is planned for 2029, handled in the Annual 2028 revision cycle. The record rests only on NFPA's public standard development page.
The standard is increasingly relevant to data centres because lithium-ion UPS batteries and on-site battery energy storage systems (BESS) fall within its scope. The topics listed on the NFPA page include energy storage systems, explosion prevention and fire prevention. This shows that the standard addresses fire and explosion risks, not only the electrical installation. This version information means the contract should state clearly which edition is referenced in the project.
This record does not use the full text, so details such as section numbers, distances or energy thresholds are not covered. For such information the standard itself must be consulted. Related documents listed are NFPA 111, UL 9540A and IEC 62933-5-2. This framework shows that fire protection design should proceed together with the battery supplier's test documents.
In design terms, when Li-ion UPS or BESS energy exceeds a configurable threshold, the record suggests prompting for ESS hazard-mitigation items: separation, explosion control and ventilation, detection, suppression and large-scale fire test evidence. These should appear in the fire checklist. As a limit, which threshold to use and which items are mandatory must be decided with local regulation and the authority having jurisdiction, from the full text of the standard.
Key points
- Standard for the Installation of Stationary Energy Storage Systems.
- Current edition 2026; next edition 2029.
- Provides minimum requirements for mitigating hazards associated with ESS.
- Next edition handled in the Annual 2028 revision cycle.
- Page topics include energy storage systems, explosion prevention and fire prevention.
- Increasingly relevant for lithium-ion UPS batteries and on-site BESS.
- Related documents: NFPA 111, UL 9540A, IEC 62933-5-2.
Using it in design
- In battery room design, require ESS hazard-mitigation items when Li-ion UPS or BESS energy exceeds a configurable threshold.
- Show separation, explosion control and ventilation, detection, suppression and large-scale fire test evidence in the fire checklist.
- Request UL 9540A test data from the manufacturer and attach it to the design file.
- Confirm the applicable energy threshold and mandatory items with the authority having jurisdiction and the full text of the standard.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Bring standards pre-checks into your project
Review model-based TS EN 50600 and Tier pre-checks, missing inputs and items requiring engineering review in SoSo CAD.
Request a demo
Who should read it
Engineers designing battery rooms, UPS and fire protection, and fire safety consultants.
Related standards
- NFPA 111
- UL 9540A
- IEC 62933-5-2
Publication details
- Authors
- National Fire Protection Association
- Publisher
- NFPA
- Year
- 2026
- Document number
- NFPA 855
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
NFPA codes are copyrighted; free read-only access requires an NFPA account, purchase otherwise. Record uses only the public NFPA development page.
Citation
National Fire Protection Association (2026). NFPA 855, Standard for the Installation of Stationary Energy Storage Systems. NFPA. NFPA 855. https://www.nfpa.org/codes-and-standards/nfpa-855-standard-development/855
Events on this subject
- Electricity Eurasia 2027
- ELECO 2026 Elektrik-Elektronik ve Biyomedikal Mühendisliği Konferansı
- 7x24 Exchange Spring Conference
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.